222
The noise canceler consists of five latch circuits connected in series and a match detector circuit.
When the noise cancellation function is not used (NCS = 0), the system clock is selected as the
sampling clock When the noise cancellation function is used (NCS = 1), the sampling clock is the
internal clock selected by CKS1 and CKS0 in TMG, the input capture input is sampled on the
rising edge of this clock, and the data is judged to be correct when all the latch outputs match. If
all the outputs do not match, the previous value is retained. After a reset, the noise canceler output
is initialized when the falling edge of the input capture input signal has been sampled five times.
Therefore, after making a setting for use of the noise cancellation function, a pulse with at least
five times the width of the sampling clock is a dependable input capture signal. Even if noise
cancellation is not used, an input capture input signal pulse width of at least 2
or 2
SUB
is
necessary to ensure that input capture operations are performed properly
Note: *
An input capture signal may be generated when the NCS bit is modified.
Figure 9-10 shows an example of noise canceler timing.
In this example, high-level input of less than five times the width of the sampling clock at the
input capture input pin is eliminated as noise.
Input capture
input signal
Sampling clock
Noise canceler
output
Eliminated as noise
Figure 9-10 Noise Canceler Timing (Example)