ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 3.
Parameter
Rating
V
DD to GND
0.3 V to +7 V
V
REF, RFB to GND
12 V to +12 V
I
OUT1, IOUT2 to GND
0.3 V to V
DD + 0.3 V
0.3 V to V
DD + 0.3 V
Operating Temperature Range
Extended Industrial (Y Version)
40°C to +125°C
Storage Temperature Range
65°C to +150°C
Junction Temperature
150°C
10-lead MSOP
θ
JA Thermal Impedance
206°C/W
Lead Temperature, Soldering
(10 secs)
300°C
IR Reflow, Peak Temperature
(<20 secs)
235°C
1 Overvoltages at SCLK, SYNC, DIN, and LDAC are clamped by internal diodes.
Current should be limited to the maximum ratings given.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods may
affect device reliability.
ESD CAUTION