4
E0C6S32
s ELECTRICAL CHARACTERISTICS
q Absolute Maximum Ratings
E0C6S32/6SA32/6SB32
Rating
Supply voltage
Input voltage (1)
Input voltage (2)
Permissible total output current *1
Operating temperature
Storage temperature
Soldering temperature / Time
Permissible dissipation *2
1:
2:
The permissible total output current is the sum total of the current (average current) that simultaneously flows from the output pins (or is draw in).
In case of plastic package (QFP5-80pin, QFP14-80pin).
Symbol
VSS
VI
VIOSC
ΣIVSS
Topr
Tstg
Tsol
PD
Value
-5.5 to 0.5
VSS - 0.3 to 0.5
VS1 - 0.3 to 0.5
10
-20 to 70
-65 to 150
260
°C, 10sec (lead section)
250
Unit
V
mA
°C
–
mW
(VDD=0V)
Rating
Supply voltage
Input voltage (1)
Input voltage (2)
Permissible total output current *1
Operating temperature
Storage temperature
Soldering temperature / Time
Permissible dissipation *2
1:
2:
The permissible total output current is the sum total of the current (average current) that simultaneously flows from the output pins (or is draw in).
In case of plastic package (QFP5-80pin, QFP14-80pin).
Symbol
VSS
VI
VIOSC
ΣIVSS
Topr
Tstg
Tsol
PD
Value
-2.0 to 0.5
VSS - 0.3 to 0.5
VS1 - 0.3 to 0.5
10
-20 to 70
-65 to 150
260
°C, 10sec (lead section)
250
Unit
V
mA
°C
–
mW
(VDD=0V)
q Recommended Operating Conditions
E0C6S32
E0C6SL32
Condition
Supply voltage
Oscillation frequency
Symbol
VSS
fOSC1
Remark
VDD=0V
Unit
V
kHz
(Ta=-20 to 70
°C)
Max.
-1.8
–
Typ.
-3.0
32.768
Min.
-3.6
–
E0C6SL32
Condition
Supply voltage
Oscillation frequency
1:
2:
When switching to heavy load protection mode. Note, however, that the ON time for BLS in the heavy load protection must be limited
to 10 msec per second of operation time.
The possibility of LCD panel display differs depending on the characteristics of the LCD panel.
Symbol
VSS
fOSC1
Remark
VDD=0V
VDD=0V, With software control *1
VDD=0V, When the analog comparator is used
Unit
V
kHz
(Ta=-20 to 70
°C)
Max.
-1.1
-0.9 *2
-1.2
–
Typ.
-1.5
32.768
Min.
-1.8
–
E0C6SB32
Condition
Supply voltage
Oscillation frequency
1:
2:
When switching to heavy load protection mode. Note, however, that the ON time for BLS in the heavy load protection must be limited
to 10 msec per second of operation time.
The possibility of LCD panel display differs depending on the characteristics of the LCD panel.
Symbol
VSS
fOSC1
Remark
VDD=0V
VDD=0V, With software control *1
VDD=0V, When the analog comparator is used
Unit
V
kHz
(Ta=-20 to 70
°C)
Max.
-1.1
-0.9 *2
-1.2
–
Typ.
-1.5
32.768
Min.
-3.6
–
E0C6SA32
Condition
Supply voltage
Oscillation frequency (1)
Oscillation frequency (2)
Symbol
VSS
fOSC1
fOSC3
Remark
VDD=0V
duty 50
±5%
Unit
V
kHz
(Ta=-20 to 70
°C)
Max.
-1.8
–
1300
Typ.
-3.0
32.768
1000
Min.
-3.6
–
300