DRV591
SLOS389
–
NOVEMBER 2001
3
www.ti.com
Terminal Functions
TERMINAL
I/O
DESCRIPTION
NAME
NO.
AGND
2
Analog ground
Connect 1
μ
F capacitor to ground for AREF voltage filtering
Analog power supply
AREF
5
O
AVDD
1
I
COSC
4
I
Connect capacitor to ground to set oscillation frequency (220 pF for 500 kHz, 1 nF for 100 kHz) when
the internal oscillator is selected; connect clock signal when an external oscillator is used
FAULT0
10
O
Fault flag 0, low when active open drain output (see application information)
FAULT1
9
O
Fault flag 1, high when active open drain output (see application information)
FREQ
32
I
Selects 500 kHz switching frequency when a TTL logic low is applied to this terminal; selects 100kHz
switching frequency when a TTL logic high is applied
IN
–
7
I
Negative differential input
IN+
6
I
Positive differential input
INT/EXT
31
I
Selects the internal oscillator when a TTL logic high is applied to this terminal; selects the use of an
external oscillator when a TTL logic low is applied to this terminal
OUT
–
14, 15, 16, 17
O
Negative bridge-tied load (BTL) output (4 pins)
OUT+
24, 25, 26, 27
O
Positive bridge-tied load (BTL) output (4 pins)
PGND
18, 19, 20, 21,
22, 23
High-current ground (6 pins)
PVDD
11, 12, 13, 28,
29, 30
I
High-current power supply (6 pins)
ROSC
3
I
Connect 120 k
resistor to AGND to set oscillation frequency (either 500 kHz or 100 kHz). Not need-
ed if an external clock is used.
SHUTDOWN
8
I
Places the amplifier in shutdown mode when a TTL logic low is applied to this terminal; places the
amplifier in normal operation when a TTL logic high is applied
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage, AVDD
,
PVDD
Input voltage, V
I
Output current, I
O
(FAULT0, FAULT1)
Continuous total power dissipation
Operating free-air temperature range, T
A
Operating junction temperature range, T
J
Storage temperature range, T
stg
Stresses beyond those listed under
“
absolute maximum ratings
”
may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under
“
recommended operating conditions
”
is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
–
0.3 V to 5.5 V
–
0.3 V to V
DD
+ 0.3 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 mA
See Dissipation Rating Table
–
40
°
C to 85
°
C
–
40
°
C to 150
°
C
–
65
°
C to 165
°
C
DISSIPATION RATING TABLE
θ
JA
(
°
C/W)
PACKAGE
θ
JC
(
°
C/W)
TA = 25
°
C
POWER RATING
VFP
GQE
29.4
1.2
4.1 W
37.8
4.56
3.3 W
This data was taken using 2 oz trace and copper pad that is soldred directly to a JEDEC
standard 4-layer 3 in
×
3 in PCB.
This package is in the Product Preview stage of development.