D11E Series Sensors
– Visible Green, Blue or White LED Light Source
page
2
Banner Engineering Corp.
Minneapolis, MN U.S.A.
www.bannerengineering.com Tel: 763.544.3164
The Signal Strength indicator is Banner’s exclusive AID (Alignment Indicating
Device, U.S. Patent #4356393). This feature makes alignment during the TEACH mode
easy and accurate and provides a means of signaling when maintenance is needed
when the sensor is in RUN mode. Whenever the pulse rate is slow, the fiber sensing
ends should be cleaned and/or the alignment checked.
TEACH Mode
Sensitivity is automatically set (and optimized) by “teaching” the sensor the light and
dark conditions. This is accomplished in TEACH mode. TEACH mode simply requires
that each of the two sensing conditions be presented to the fiber optics. When the
push button is clicked, the sensor samples the sensing condition and registers it into
memory. After the second sensing condition is registered, the D11E automatically sets
the sensitivity to the optimum value for the application, and then returns to RUN
mode.
NOTE: There is a period of a few seconds at the end of TEACH mode before RUN
mode begins.
Light or Dark Operate Selection
The two sensing conditions may be presented in either order: the light condition first,
and then the dark condition, or vice versa. The condition presented first is the
condition for which the output will energize. In other words, the output will be light
operated if the light condition is TEACH condition #1, or the output will be dark
operated if the dark condition is TEACH condition #1.
RUN Mode
Normal operation of the D11 Expert is called RUN mode. The LED indicators operate
in RUN mode, as follows:
Indicator
LED Color
Function
Power
"ON"
Green
1) On steadily whenever power is applied
2) Flashes at approximately 4Hz to indicate that the
output is overloaded
Output
Indicator
Yellow
Follows the action of the output:
On when the output is energized
Off when the output is de-energized
Signal
Strength
Red
Lights whenever the sensor "sees" its modulated
light source and pulses at a rate which is
proportional to the received light signal strength
SIG
Signal Strength Indicator
Output Indicator
Power ON Indicator
Programming Push Button
Figure 1. D11E
Expert
Features
相關(guān)PDF資料
PDF描述
D1201UK Gold Metallised Multi-Purpose Silicon DMOS RF FET(10W-12.5V-500MHz,Single Ended)(鍍金多用DMOS射頻硅場(chǎng)效應(yīng)管(10W-12.5V-500MHz,單端式))
D1201 METAL GATE RF SILICON FET
D1201UK METAL GATE RF SILICON FET
D1202UK Gold Metallised Multi-Purpose Silicon DMOS RF FET(20W-12.5V-500MHz,Single Ended)(鍍金多用DMOS射頻硅場(chǎng)效應(yīng)管(20W-12.5V-500MHz,單端式))
D1202 METAL GATE RF SILICON FET
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
D11EST 制造商:OSRAM 功能描述:LAMP DULUX EL11W ES
D11N0 制造商:Schneider Electric 功能描述:OPERATING MECHANISM AUX CONTACT GOULD
D11N0C 制造商:Schneider Electric 功能描述:KIT_INTERL 制造商:Schneider Electric 功能描述:Electromechanical Switch Disconnect Switch N.O./N.C. DPST
D11N0C2 制造商:Schneider Electric 功能描述:D11N0C2 制造商:SCHNEIDER ELECTRIC 功能描述:D11N0C2
D11NC 制造商:Schneider Electric 功能描述:OPERATING MECHANISM AUX CONTACT GOULD 制造商:SCHNEIDER ELECTRIC 功能描述:Electromechanical Switch Disconnect Switch N.C. SPST