13
SCDCT1611 Rev A
BC Criteria for Valid Transactions
Valid Transactions result in generation of GOOD XFER (INT 0) Interrupt.
Invalid Transfer result in generation of INVALID TRANSFER (INT 1) Interrupt.
See Transaction Word for additional Status Word Criterion (i.e. bit masks)
General Validity Criteria - Applies to all transfers
A. Bus must be quiet, i.e. no additional data words, status words or command words after correct RT response
before transaction is declared valid.
B. If data is returned, word count, must be correct. Data must also be contiguous, i.e. no gaps.
C. RTU Address(s) must be correct in returned status word(s).
D. RTU must respond within 14μsec (except for non RT to RT Broadcast).
E.
No bits set in returned status word(s), except where masked in transaction word.
Interrupts In BC Mode
Transaction Type
Specific Validity Criteria
1. Normal Data Transfer
A. RT to BC
B. BC to
RT
C. Broadcast
(Tx/Rx = 1)
(Tx/Rx = 0)
(Tx/Rx = 0)
Status, then Valid Message
Status
No Status
2. RT to RT Transfer
A. Normal
B. Broadcast
(Tx/Rx = 1)
(Tx/Rx = 1)
Status, Valid Message,then Status
Status, then Valid Message only
3. Mode (no data)
A. Normal
B. Broadcast
Status
No Status
4. Mode (associated data)
A. Normal
B. Broadcast
Status
No Status
5. Mode (returned data)
Status, then returned data
BC Interrupt Name
Signal Name
Conditions and Actions
Good Transfer
INT 0
1. Indicates fully valid transaction.
2. Initiates next poll operation, when in polling mode.
Invalid Transfer
INT 1
1. Non masked bits set (includes reserved bits).
2. No status (2 for non BCST RT to RT) word returned.
3. Status word has incorrect address.
4. Fail safe time out (1 millisec)for bus (RTU) to go quiet i.e.
RTU loudmouthing.
5. Incorrect number of data words.
6. Busy (even if busy masked) when RTU should receive or
transmit data.
Note: busy mask only masks busy for mode cmds.
Poll Operation Complete
INT 2
1. Indicates end of poll,when end of poll is a valid transaction.
2. Delayed from good transfer interrupt.
3. Initiates poll sequence again (from offset) if in continuous
mode.
4. If the I/O command "continue at next transaction" is issued at
the last transaction command, this interrupt will be issued.
相關(guān)PDF資料
PDF描述
CT1698 CT1698 MIL-STD-1397 Type E 10MHz Low Level Serial Interface
CT1698FP CT1698 MIL-STD-1397 Type E 10MHz Low Level Serial Interface
CT1775 CT1775 Universal MacAir/1553 Dumb RTU Hybrid
CT1815 CT1815 10MHz Low Level Serial Interface for MIL-STD-1397 Type D
CT1815FP CT1815 10MHz Low Level Serial Interface for MIL-STD-1397 Type D
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CT1612 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU
CT1612DB38400C0FLHA1 功能描述:CRYSTAL UNIT WITH THERMISTOR, 1. 制造商:avx corp/kyocera corp 系列:* 零件狀態(tài):新產(chǎn)品 標(biāo)準(zhǔn)包裝:1
CT1612FP 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:MIL-STD-1553/ARINC Bus Controller/RTU
CT1616 制造商:EDSYN 功能描述:
CT16-16P 制造商:ITT Interconnect Solutions 功能描述:330-0351-016