ADG1208/ADG1209
Rev. B | Page 7 of 20
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 3.
Parameter
Rating
VDD to VSS
35 V
VDD to GND
0.3 V to +25 V
VSS to GND
+0.3 V to 25 V
VSS 0.3 V to VDD + 0.3 V or
30 mA (whichever occurs first)
Continuous Current, S or D
30 mA
Peak Current, S or D (Pulsed at
1 ms, 10% Duty Cycle Maximum)
100 mA
Operating Temperature Range
Industrial (Y Version)
–40°C to +125°C
Storage Temperature
–65°C to +150°C
Junction Temperature
150°C
θJA, Thermal Impedance, TSSOP
112°C/W
θJA, Thermal Impedance, LFCSP_VQ
30.4°C/W
θJA, Thermal Impedance, SOIC_N
77°C/W
Reflow Soldering Peak
Temperature (Pb-Free)
260(+0/5)°C
1 Overvoltages at A, EN, S, or D are clamped by internal diodes. Current should
be limited to the maximum ratings given.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION