REV. 0
AD9226
–5–
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the AD9226 features proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
ABSOLUTE MAXIMUM RATINGS
1
With
Pin Name
Respect to
Min
Max
Unit
AVDD
DRVDD
AVSS
AVDD
REFCOM
CLK, MODE
Digital Outputs
VINA, VINB
VREF
SENSE
CAPB, CAPT
OEB
2
CM LEVEL
2
VR
2
Junction Temperature
Storage Temperature
Lead Temperature (10 sec)
AVSS
DRVSS
DRVSS
DRVDD
AVSS
AVSS
DRVSS
AVSS
AVSS
AVSS
AVSS
DRVSS
AVSS
AVSS
–
0.3
–
0.3
–
0.3
–
6.5
–
0.3
–
0.3
–
0.3
–
0.3
–
0.3
–
0.3
–
0.3
–
0.3
–
0.3
–
0.3
+6.5
+6.5
+0.3
+6.5
+0.3
AVDD + 0.3
DRVDD + 0.3
AVDD + 0.3
AVDD
+ 0.3
AVDD
+ 0.3
AVDD
+ 0.3
DRVDD + 0.3
AVDD
+ 0.3
AVDD
+ 0.3
150
+150
300
V
V
V
V
V
V
V
V
V
V
V
V
V
V
°
C
°
C
°
C
–
65
NOTES
1
Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum ratings
for extended periods may affect device reliability.
2
LQFP package.
THERMAL RESISTANCE
θ
JC
SSOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
°
C/W
θ
JA
SSOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63.3
°
C/W
θ
JC
LQFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
°
C/W
θ
JA
LQFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76.2
°
C/W
EXPLANATION OF TEST LEVELS
Test Level
I.
100% production tested.
II. 100% production tested at 25
°
C and sample tested at
specified temperatures. AC testing done on sample basis.
III. Sample tested only.
IV. Parameter is guaranteed by design and characterization
testing.
V. Parameter is a typical value only.
VI. All devices are 100% production tested at 25
°
C; sample tested
at temperature extremes.
ORDERING GUIDE
Model
Temperature Range
–
40
°
C to +85
°
C
–
40
°
C to +85
°
C
Package Description
Package Option
AD9226ARS
AD9226AST
AD9226-EB
AD9226-LQFP-EB
28-Lead Shrink Small Outline (SSOP)
48-Lead Thin Plastic Quad Flatpack (LQFP)
Evaluation Board (SSOP)
Evaluation Board (LQFP)
RS-28
ST-48