–3–
REV. 0
AD9005B
Commercial
0
8
C to +70
8
C
AD9005BKM
Typ
Military
–55
8
C to +125
8
C
AD9005BTM
Typ
Test
Level
Parameter
Temp
Min
Max
Min
Max
Units
DIGITAL OUTPUTS
Logic “l(fā)” Voltage (2 mA Source)
Logic “0” Voltage (4 mA Sink)
Logic Coding
Full
Full
Full
I
I
IV
2.4
2.4
V
V
0.4
0.4
Offset Binary
Offset Binary
POWER SUPPLY
Supply Voltage +V
S
Supply Current Analog +V
S
Supply Current Digital +V
S
Supply Voltage –V
S
Supply Current Analog –V
S
Supply Current Digital –V
S
Nominal Power Dissipation
PSRR
13, 15
Full
Full
Full
Full
Full
Full
Full
+25
°
C
VI
VI
VI
VI
VI
VI
VI
I
4.75
5.0
180
43
–5.2
210
65
3.2
0.01
5.25
240
80
–5.45
320
110
4.0
0.02
4.75
5.0
180
43
–5.2
210
65
3.2
0.01
5.25
240
80
–5.45
320
110
4.0
0.02
V
mA
mA
V
mA
mA
W
%/%
–4.95
–4.95
NOTES
1
Absolute maximum ratings are limiting values, to be applied individually, and beyond which the serviceability of the circuit may be impaired. Functional oper-
ation under any of these conditions is not necessarily implied. Exposure to absolute rating conditions for extended periods of time may affect device reliability.
1
2
Maximum junction temperature should not be allowed to exceed +175
°
C. Hybrid thermal model:
t
= t
AMBIENT
+ P
DISSIPATION
×
(
θ
CA
) + T
S
– T
C
) max
where (T
– T
46-lead metal DIP:
θ
= 14
°
C/W in still air;
θ
= 6
°
C/W with 500 LFPM air flow.
1
3
Determined by 3 dB reduction in reconstructed output.
1
4
1nput at 1 dB below full scale.
1
5
Measured at 10 MHz encode rate.
1
6
Measured from ENCODE in to data out for LSB only.
1
7
For full-scale step input; 12-bit accuracy is attained in the specified time.
1
8
Recovers to 12-bit accuracy in specified time following 200% full-scale input voltage.
1
9
Excludes pipeline delay of two clock cycles (see timing diagram).
10
Worst case spurious in-band signal relative to input level.
11
RMS signal to RMS noise, including harmonics.
12
Worst case spurious in-band signal relative to level of input tones, which are both –7 dB below full scale.
13
Sensitivity of full-scale gain error with respect to power supply variation within supply Min/Max limits.
14
ENCODE signal rise and fall times should be less than 5 ns for normal operation. Transition from “0” to “1” initiates conversion.
15
PSRR is tested over given voltage range.
Specifications subject to change without notice.
EXPLANATION OF TEST LEVELS
Test Level
I
– 100% production tested.
II – 100% production tested at +25
°
C, and sample tested at
specified temperatures.
III – Periodically sample tested only.
IV – Parameter is guaranteed by design and characterization
testing.
V – Parameter is a typical value only.
VI – All devices are 100% production tested at +25
°
C. 100%
production tested at temperature extremes for military
temperature devices. Guaranteed, not tested, for com-
mercial temperature range
ORDERING GUIDE
Model
Temperature Range
Package Description
Package Option*
AD9005BKM
AD9005BTM
AD9005/PCB
0
°
C to +70
°
C
–55
°
C to + 125
°
C
0
°
C to +70
°
C
46-Lead DIP, Commercial Temperature
46-Lead DIP, Military Temperature
AD9005 Evaluation Board
M-46
M-46