AD28msp01
REV. A
–10–
Data Register 1
Interpolation Filter Input Register (write-only): The 16-bit twos
complement values written to this register are input to the
resampling interpolation filter.
Data Register 2
address = 0x08
ADC Output Register (read-only): The 16-bit twos complement
values read from this register are the output of the AD28msp01’s
analog-to-digital converter.
Data Register 3
address = 0x09
Interpolation Filter Output Register (read-only): The 16-bit
twos complement values read from this register are the output of
the resampling interpolation filter.
Addresses 0x0A—0x1F are reserved.
Table II contains the register addresses.
address = 0x07
Table II. Register Addresses
Address
Bits 4–0 Register
Description
00000
Control Register 0 Data rate and synchronization
rate selects, interpolation filter
enable
Control Register 1 Filter bypass, test, power-down
mode bits, V.32ter mode select
bits
Control Register 2 ADC bit and baud rate selects
Control Register 3 DAC bit and baud rate selects
Control Register 4 Receive phase adjust
Control Register 5 Transmit phase adjust
Data Register 0
DAC input register
Data Register 1
Interpolation filter input register
Data Register 2
ADC output register
Data Register 3
Interpolation filter output register
Reserved
. . . . . . . .
. . . . . . . .
Reserved
00001
00010
00011
00100
00101
00110
00111
01000
01001
01010
. . . .
. . . .
11111
Transferring Data and Control Words to the AD28msp01
Data and control word transfers to the AD28msp01 can only be
initiated by the host processor. When transferring data to the
AD28msp01, the host processor specifies the destination regis-
ter by first transmitting a 16-bit address word (Figure 6) and
then transmitting the 16-bit data word. The read/write bit in the
address word must be deasserted. The serial data stream from
the host processor will consist of a sequence of alternating ad-
dress and data words. The AD28msp01 will not write the target
register until both the address word and data word are com-
pletely transferred.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
READ/WRITE
1 = read
0 = write
Address bits [4...0]
See Table I.
Figure 6. Address Word
Example
Transferring the following 16-bit words to the AD28msp01 will
initialize Control Registers 0–3.
Word Transferred
Description
0x0000
Control Register 0 Address Word
0x0254
Write this value to Control Register 0
0x0002
Control Register 2 Address Word
0x0031
Write this value to Control Register 2
0x0003
Control Register 3 Address Word
0x0032
Write this value to Control Register 3
0x0001
Control Register 1 Address Word
0x0018
Write this value to Control Register 1
Note that in this example the power-down bits in Control Regis-
ter 1 are released (set to 1) only after the AD28msp01 is fully
configured by writing to Control Registers 0, 2, and 3.
Transferring Data from the AD28msp01 to the Host
Data transfers to the host processor can only be initiated by the
AD28msp01. When transferring data the AD28msp01 first
specifies the source register by transferring a 16-bit address
word and then transfers the contents of the source register. Bits
5–14 of the address word will always be forced to zero. When
transferring data, the serial data stream from the AD28msp01
will consist of a sequence of alternating address and data words.
Transferring Control Words from the AD28msp01 to the Host
All control registers in the AD28msp01 are host-readable. To
read a control register, the host must transmit a 16-bit address
word with the Read/ Write bit set, then transmit a dummy data
word. The AD28msp01 will respond by first completing any
AD28msp01-to-Host transfer in progress. As soon as the
dummy data word is received, the device will transfer a 16-bit
word with the control register address and then transmit the
contents of the control register.
Example
The following data streams show how a host can read the con-
tents of an AD28msp01 control register:
Host
AD28msp01
Transfer
Transfer
0x8001
0x1234
0x
0x
0x0001
0x0023
Description
Read Control Register 1
Dummy data word
AD28msp01 completes data
Transfer in progress
Address word
Contents of Control Register 1
Serial Port Timing
All serial transfers are synchronous. The receive data (SDI) and
receive frame sync (SDIFS) are clocked into the device on the
falling edge of SCLK. The receive frame sync (SDIFS) must be
asserted one SCLK cycle before the first data bit is transferred.
When receiving data, the AD28msp01 ignores the receive frame
sync pin until the least significant bit is being received.
When transmitting data, the AD28msp01 asserts transmit frame
sync (SDOFS) and transmit data (SDO) synchronous with the
rising edge of SCLK. Transmit frame sync is transmitted one
SCLK cycle before the first data bit is transferred.
Operating Modes
The AD28msp01 is capable of operating in several different
modes, as described below.