Thyristors Used as AC Static Switches and Relays
Introduction
Since the SCR and the triac are bistable devices, one of their 
broad areas of application is in the realm of signal and power 
switching. This application note describes circuits in which these 
thyristors are used to perform simple switching functions of a 
general type that might also be performed non-statically by vari-
ous mechanical and electromechanical switches. In these appli-
cations, the thyristors are used to open or close a circuit 
completely, as opposed to applications in which they are used to 
control the magnitude of average voltage or energy being deliv-
ered to a load. These latter types of applications are described in 
detail in “Phase Control Using Thyristors” (AN1003).
Static AC Switches
Normally Open Circuit
The circuit shown in Figure AN1007.1 provides random (any-
where in half-cycle), fast turn-on (<10 μs) of AC power loads and 
is ideal for applications with a high-duty cycle. It eliminates com-
pletely the contact sticking, bounce, and wear associated with 
conventional electromechanical relays, contactors, and so on. As 
a substitute for control relays, thyristors can overcome the differ-
ential problem; that is, the spread in current or voltage between 
pickup and dropout because thyristors effectively drop out every 
half cycle. Also, providing resistor R
 is chosen correctly, the cir-
cuits are operable over a much wider voltage range than is a 
comparable relay. Resistor R
1
 is provided to limit gate current 
(I
) peaks. Its resistance plus any contact resistance (R
) of the 
control device and load resistance (R
) should be just greater 
than the peak supply voltage divided by the peak gate current 
rating of the triac. If R
 is set too high, the triacs may not trigger 
at the beginning of each cycle, and phase control of the load will 
result with consequent loss of load voltage and waveform distor-
tion. For inductive loads, an RC snubber circuit, as shown in Fig-
ure AN1007.1, is required. However, a snubber circuit is not 
required when an alternistor is used.
Figure AN1007.2 illustrates an analysis to better understand a 
typical static switch circuit. The circuit operation occurs when 
switch S
1
 is closed, since the triac Q
1
 will initially be in the block-
ing condition. Current flow will be through load R
, S
, R
, and 
gate to MT1 junction of the thyristor. When this current reaches 
the required value of I
GT
, the MT2 to MT1 junctions will switch to 
the conduction state and the voltage from MT2 to MT1 will be V
. 
As the current approaches the zero crossing, the load current will 
fall below holding current turning the triac Q
1
 device off until it is 
refired in the next half cycle. Figure AN1007.3 illustrates the volt-
age waveform appearing across the MT2 to MT1 terminals of Q
1
. 
Note that the maximum peak value of current which S
1
 will carry 
would be 25 mA since Q
 has a 25 mA maximum I
 rating. Addi-
tionally, no arcing of a current value greater than 25 mA when 
opening S
 will occur when controlling an inductive load. It is 
important also to note that the triac Q
 is operating in Quadrants I 
and III, the more sensitive and most suitable gating modes for tri-
acs. The voltage rating of S
 (mechanical switch or reed switch) 
must be equivalent to or greater than line voltage applied.
Figure AN1007.1
Basic Triac Static Switch
Figure AN1007.2
Analysis of Static Switch
Load
R
L
R
1
100 
R
2
100 
S
1
Control
Device
Reed
Switch
For
Inductive
Loads
C
0.1 μF
Triac
R
1
≥√2
V
   (R
L
 + R
C
)   Where I
GTM
 is Peak Gate Current
                     Rating of Triac
V
RMS
MT1
I
GT
MT2
AC Voltage Input
120 V rms, 60 Hz
V
IN
R
L
S
1
I
GT
V
GT
Q
1
+
-
Load
R
1
G
Q2008L4