8
Note:
collet nut tightening torque: maximum 0.25 Nm (1N = 0.102 kg)
4
4
1
Straight plug
Free receptacle
Fixed receptacle
nut fixing
1
2
2
3
3
Straight plug
Free receptacle
Fixed receptacle
nut fixing
Type C Cable Clamping
This system has an earthing sleeve
and a collet
which is compressed by the collet nut
to ensure a good clamp
onto the cable. When assembling the connector, the cable shield is gripped between the earthing sleeve and the collet.
Cable Fixing
Cable fixing onto LEMO connectors is determined by the
connector model. This is achieved either with a cable
collet system or with hexagonal crimping (MIL-C-22520F,
type 2).
The collet system cable fixing is made without any spe-
cial tooling. The crimping method guarantees a good
electrical continuity of the shield which improves greatly
the shielding efficiency of the cable/connector link.
Component
Earthing sleeve
Collet
Crimp ferrule
Collet nut
Surface Treatment
(μm)
Cu
0.5
0.5
0.5
0.5
Material (Standard)
Ni
3
3
3
3
Brass (UNS C 38500)
Brass (UNS C 38500)
Copper (UNS C 18700)
Brass (UNS C 38500)
Material and Treatment
Type E Crimping
The back end of the crimp nut
which receives the shield braid, is milled to ensure good conductivity once crimped.