12
FFA.00.250.NTAC29
= straight plug with cable collet, series 00, coaxial type (50
), outer shell in nickel-plated brass,
PTFE insulator, male solder contact, C type collet of 2.9 mm diameter.
FFA
00
Type: 250 = coaxial (50
)
N = brass nickel-plated
C = brass chrome-plated
Housing:D = brass gold-plated
L = aluminum alloy
G = PEEK
3)
Cable :
Cable fixing type:
C = with cable collet
E = crimp
Variant
2)
250
Series: 00
Model: (page 13)
N
T
A
C 29
Insulator:T = PTFE
Straight receptacle
ERA
00
Type: 250 = coaxial (50
)
Variant
2)
250
Series: 00
Model: (page 16)
N
T
L
Contact type:
A = male to solder
C = male to crimp
L = female to solder
M = female to crimp
N = brass nickel-plated
C = brass chrome-plated
1)
Housing: D = brass gold-plated
K = brass black chrome
1)
L = aluminum alloy
1)
ERA.00.250.NTL
= fixed receptacle, nut fixing, series 00, coaxial type (50
), outer shell in nickel-plated brass, PTFE
insulator, female solder contact.
Contact type:
A = male to solder
C = male to print
L = female to solder
M = female to print
Straight fixed coupler
RAD
00
Type: 250 = coaxial (50
)
Variant
2)
250
Series: 00
Model: (page 21)
N
T
M
N = brass nickel-plated
C = brass chrome-plated
Housing: D = brass gold-plated
K = brass black chrome
L = aluminum alloy
RAD.00.250.NTM
= straight fixed coupler, nut fixing, series 00, coaxial type (50
), outer shell in nickel-plated brass,
PTFE insulator, female-female contact.
Contact type
4)
:
A = male-female
C = male-male
E = male-male-female
5)
F = female-female-male
5)
L = female-male
M= female-female
Note:
1) treatment not available for the printed circuit models
2) the “variant” position in the reference is used to specify the anodized color of the housing in aluminum alloy (page 11) or models with a collet nut for
fitting a strain relief “Z”. The strain relief can be ordered separately as indicated in the “Accessories” section.
3) available for the FFA model only
4) concerning the straight fixed couplers with nut fixing RAD and SWH, the first contact type mentioned is always the contact at the flange end.
5) used only for models: FTA, FTL and FTY.
Part Number Example
Straight plug with cable collet
Insulator:T = PTFE
Insulator:T = PTFE