A49LF004 
PRELIMINARY      (November, 2003, Version 0.0) 
10 
AMIC Technology, Corp.
Table 6: Lock Register Bit Definition
ADDRESS/ADDRESS MULTIPLEXED (A/A 
MUX) MODE 
Device Operation 
Commands are used to initiate the memory operation 
functions of the device. The data portion of the software 
command sequence is latched on the rising edge of WE#. 
During the software command sequence the row address is 
latched on the falling edge of R/C# and the column address 
is latched on the rising edge of R/C#. Refer to Table 7 and 
Table 8 for operation modes and the command sequence. 
Read 
The Read operation of the A49LF004 device is controlled by 
OE#. OE# is the output control and is used to gate data from 
the output pins. Refer to the Read cycle timing diagram, 
Figure 10 for further details. 
Reset 
A V
IL
 on RST# pin initiates a device reset. 
Byte-Program Operation 
The A49LF004 device is programmed on a byte-by-byte 
basis. Before programming, one must ensure that the block, 
in which the byte which is being programmed exists, is fully 
erased. The Byte-Program operation is initiated by executing 
a four-byte command load sequence for Software Data 
Protection with address and data in the last byte sequence. 
During the Byte-Program operation, the row address (A10-
A0) is latched on the falling edge of R/C# and the column 
Address (A21-A11) is latched on the rising edge of R/C#. 
The data bus is latched in the rising edge of WE#. See 
Figure 11 for Program operation timing diagram, Figure 14 
for timing waveforms, and Figure 19 for its flowchart. During 
the Program operation, the only valid reads are Data# 
Polling and Toggle Bit. During the internal Program 
operation, the host is free to perform additional tasks. Any 
commands written during the internal Program operation will 
be ignored. 
Data 
Reserved 
Bit 7:3 
Read-Lock 
Bit 2 
Lock-Down
Bit 1 
Write-Lock
Bit 0 
Function 
00h 
00000 
0 
0 
0 
Full Access. 
01h 
00000 
0 
0 
1 
Write locked. Default state at power-up. 
02h 
00000 
0 
1 
0 
Locked open (full access locked down). 
03h 
00000 
0 
1 
1 
Write-locked down. 
04h 
00000 
1 
0 
0 
Read locked. 
05h 
00000 
1 
0 
1 
Read and Write locked. 
06h 
00000 
1 
1 
0 
Read-locked down 
07h 
00000 
1 
1 
1 
Read- and Write-locked down 
Data 
Function 
7:3 
Reserved 
Read-Lock 
1 = Prevents read operations in the block where set 
0 = Normal operation for reads in the block where clear. This is the default state. 
Lock-Down 
1 = Prevents further set or clear operations to the Write-Lock and Read-Lock bits. Lock-Down only can be set 
but not clear. The block will remain lock-down until reset (with RST# or INIT# being Low), or until the device 
is power-on reset. 
0 = Normal operation for Write-Lock and Read-Lock bit altering in the block where clear. This is the default state.
Write-Lock 
1 = Prevents program or erase operations in the block where set. This is the default state. 
0 = Normal operation for programming and erase in the block where clear. 
2 
1 
0