SLLS067G AUGUST 1990 REVISED APRIL 2006
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
schematics of inputs and outputs
Input
VCC
EQUIVALENT OF D, RE, and
DE INPUTS
TYPICAL OF RECEIVER OUTPUT
Output
VCC
VCC
100 k
NOM
A Port Only
18 k
NOM
3 k
NOM
A or B
100 k
NOM
B Port Only
1.1 k
NOM
TYPICAL OF A AND B I/O PORTS
absolute maximum ratings
Supply voltage, V
CC
(see Note 1)
Voltage range at any bus terminal
Input voltage, V
I
(D, DE, R, or RE)
Receiver output current, I
O
Continuous total power dissipation
Storage temperature range, T
stg
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential I/O bus voltage, are with respect to network ground terminal.
7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 V to 15 V
0.3 V to V
CC
+ 0.5 V
10 mA
See Dissipation Rating Table
65
°
C to 150
°
C
DISSIPATION RATING TABLE
PACKAGE
THERMAL
MODEL
Low K
High K
TA < 25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
5.0 mW/
°
C
8.4 mW/
°
C
8.0 mW/
°
C
8.4 mW/
°
C
11.0 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
TA = 110
°
C
POWER RATING
D
526 mW
301 mW
226 mW
—
882 mW
504 mW
378 mW
—
P
840 mW
480 mW
360 mW
—
JG
1050 mW
672 mW
546 mW
210 mW
FK
1375 mW
880 mW
715 mW
440 mW
In accordance with the low effective thermal conductivity metric definitions of EIA/JESD 513.
In accordance with the high effective thermal conductivity metric definitions of EIA/JESD 517.