3850 Group (Spec. H/A)
SINGLE-CHIP 8-BIT CMOS MICROCOMPUTER
MITSUBISHI MICROCOMPUTERS
(3) Standard serial I/O Mode
The standard serial I/O mode inputs and outputs the software
commands, addresses and data needed to operate (read, pro-
gram, erase, etc.) the internal flash memory. This I/O is clock
synchronized serial. This mode requires the exclusive external
equipment (serial programmer).
The standard serial I/O mode is different from the parallel I/O
mode in that the CPU controls flash memory rewrite (uses the
CPU rewrite mode), rewrite data input and so forth. The standard
serial I/O mode is started by connecting
H
to the P2
6
(S
CLK
) pin
and
H
to the P4
1
(INT
0
) pin and
H
to the CNV
SS
pin (apply 4.5
V to 5.5 V to Vpp from an external source), and releasing the re-
set operation. (In the ordinary microcomputer mode, set CNVss
pin to
L
level.)
This control program is written in the Boot ROM area when the
product is shipped from Mitsubishi. Accordingly, make note of the
fact that the standard serial I/O mode cannot be used if the Boot
ROM area is rewritten in parallel I/O mode. Figure 65 shows the
pin connection for the standard serial I/O mode.
In standard serial I/O mode, serial data I/O uses the four serial I/O
pins S
CLK1
, RxD, TxD and S
RDY1
(BUSY). The S
CLK1
pin is the
transfer clock input pin through which an external transfer clock is
input. The TxD pin is for CMOS output. The S
RDY1
(BUSY) pin
outputs
L
level when ready for reception and
H
level when re-
ception starts.
Serial data I/O is transferred serially in 8-bit units.
In standard serial I/O mode, only the User ROM area shown in
Figure 44 can be rewritten. The Boot ROM area cannot.
In standard serial I/O mode, a 7-byte ID code is used. When there
is data in the flash memory, commands sent from the peripheral
unit (programmer) are not accepted unless the ID code matches.
Outline Performance (Standard Serial I/O
Mode)
In standard serial I/O mode, software commands, addresses and
data are input and output between the MCU and peripheral units
(serial programmer, etc.) using 4-wire clock-synchronized serial
I/O (serial I/O1).
In reception, software commands, addresses and program data
are synchronized with the rise of the transfer clock that is input to
the S
CLK
pin, and are then input to the MCU via the RxD pin. In
transmission, the read data and status are synchronized with the
fall of the transfer clock, and output from the TxD pin.
The TxD pin is for CMOS output. Transfer is in 8-bit units with LSB
first.
When busy, such as during transmission, reception, erasing or
program execution, the S
RDY1
(BUSY) pin is
H
level. Accord-
ingly, always start the next transfer after the S
RDY1
(BUSY) pin is
L
level.
Also, data and status registers in a memory can be read after in-
putting software commands. Status, such as the operating state of
the flash memory or whether a program or erase operation ended
successfully or not, can be checked by reading the status register.
Here following explains software commands, status registers, etc.
相關(guān)PDF資料
PDF描述
386M-E1 LOW VOLTAGE AUDIO POWER AMPLIFIER
3886GROUP SINGLE-CHIP 8-BIT CMOS MICROCOMPUTER
38920000230 Repeater
38B5 SINGLE-CHIP 8-BIT CMOS MICROCOMPUTER
38C1 DIODE ZENER SINGLE 200mW 24Vz 0.05mA-Izt 0.05 0.05uA-Ir 18.2 SOD-323 3K/REEL
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
3850 02 30 00 制造商:Lumberg Connect GmbH 功能描述:
3850 07 00 02 制造商:Lumberg Connect GmbH 功能描述:
3850 20 00 09 制造商:Lumberg 功能描述:21005
3850 A20928G 制造商:LG Corporation 功能描述:LABEL, ENERGY
3850(SPEC 制造商:未知廠家 制造商全稱(chēng):未知廠家 功能描述:3850Group(Spec. H) USER'S MANUALHardware Manual & Device User's Manual 2969K/SEP.18.03