OSU 250 V
ITU-T K.20
UL 1459
GR 1089
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Order No.
Rated current In
Voltage
Pre-arcing
Lightning
Power
AC 600 V
1000 V
Rated
drop
I2t, typ.
Surge
Induction
Contact
40A / 1,5s
voltageg Un
at In, typ.
10 x1kV/10/700 s AC 300 V / 0,5 A
AC 250 V 15 min
7A / 5s
50 x 10/1000 s
mV
A2sIpuls max.
5 x 200 ms
I
SC max.
2,2A / 30 min
Ipuls max.
2070.0010.XX 250 mA / 250 V
435
0,009
3,9 A (1)
100 A
< 1,9 A (5)
2070.0011.XX 315 mA / 250 V
395
0,017
4,3 A (1)
100 A
< 1,9 A (5)
2070.0012.XX 400 mA / 250 V
230
0,02
5,8 A (1)
100 A
< 3,1 A (5)
2070.0013.XX 500 mA / 250 V
190
0,04
10,7 A (1)
100 A
< 5,1 A (5)
2070.0014.XX 630 mA / 250 V
170
0,08
16,5 A (1)
100 A
< 9,2 A (5)
2070.0015.XX 800 mA / 250 V
200
0,13
22,5 A (1)
100 A
< 14,5 A (5)
2070.0016.XX 1
A / 250 V
170
0,23
27,5 A (1)
100 A
< 14,5 A (5)
2070.0017.XX 1,25 A / 250 V
150
0,47
43,5 A (1)
100 A
< 14,5 A (5)
2070.0018.XX 1,6
A / 250 V
150
0,84
67,5 A (1)
100 A
< 14,5 A (5)
2070.0019.XX 2
A / 250 V
140
1,4
67,5 A (1)
100 A
< 14,5 A (5)
2070.0020.XX 2,5
A / 250 V
130
2,6
67,5 A (1)
100 A
< 14,5 A (5)
2070.0021.XX 3,15 A / 250 V
130
4,3
67,5 A (1)
100 A
< 14,5 A (5)
Packaging see page 167
Pre-arcing time/current characteristic (at Ta 23 °C)
Breaking capacity
Standards
Series
Rated current In
1 In
1,25 In
2 In
4 In
10 In
min.
max.
min.
max.
OSU 125 V
250 mA–3,15 A
4 h
–
1 s
10 ms
–
AC 300 A / 125 V
UL 248-14
p. f. 1
CSA C.22.2
DC 400 A / 125 V
No. 248.14
OSU 250 V
250 mA–3,15 A
–
1 h
IEC/UL
CSA
1 ms
10 ms
IEC: L
IEC 127-4/2
120 s
60 s
AC 100 A / 250 V
UL 248-14
p. f. 1
CSA C.22.2
DC 100 A / 250 V
No. 248.14
1. Technical data
Schurter, Inc. Phone 707-778-6311 Fax 707-778-6401 E-mail: info@schurterinc.com Website http://www.schurterinc.com
162
Surge Tolerant Surface Mount Fuses
2. Order No.
OSU 125 V fuses for surface mounting
can be soldered directly onto printed circuit board or
inserted into surface mount fuseholder
OSU 250 V fuses for surface mounting
can be soldered directly onto printed circuit board or
inserted into surface mount fuseholder
Solder pads
1:1
NEW
OSU 125 V
ITU-T K.20
UL 1459
GR 1089
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Order No.
Rated current In
Voltage
Pre-arcing
Lightning
Power
AC 600 V
1000 V
Rated
drop
I2t, typ.
Surge
Induction
Contact
40A / 1,5s
voltage Un
at In, typ.
10 x1kV/10/700 s AC 300 V / 0,5 A
AC 250 V 15 min
7A / 5s
50 x 10/1000 s
mV
A2sIpuls max.
5 x 200 ms
I
SC max.
2,2A / 30 min
Ipuls max.
2060.0006.XX 250 mA / 125 V
990
0,0058
2,5 A (1)
50.5 A
< 1,5 A (5)
2060.0043.XX 350 mA / 125 V
990
0,0076
4,5 A (1)
25,5 A
< 1,5 A (5)
2060.0044.XX 375 mA / 125 V
990
0,0130
4.6 A (1)
25,5 A
< 1,5 A (5)
2060.0007.XX 400 mA / 125 V
960
0,016
5,8 A (1)
25,5 A
< 1,5 A (5)
2060.0045.XX 500 mA / 125 V
300
0,010
7,7 A (1)
25,5 A
< 2,5 A (5)
2060.0008.XX 630 mA / 125 V
290
0,020
10,5 A (1)
25,5 A
< 4,6 A (5)
2060.0046.XX 750 mA / 125 V
260
0,031
13,5 A (1)
25,5 A
< 7,5 A (5)
2060.0009.XX 1
A / 125 V
220
0,086
16,5 A (1)
25,5 A
< 9,3 A (5)
2060.0010.XX 1,25 A / 125 V
220
0,14
25,5 A (1)
25,5 A
< 14,5 A (5)
2060.0047.XX 1,5
A / 125 V
200
0,24
30,5 A (1)
8,3 A
14,5 A (5)
2060.0011.XX 1,6
A / 125 V
200
0,27
33,5 A (1)
12,5 A
< 14,5 A (5)
2060.0012.XX 2
A / 125 V
200
0,44
45,5 A (1)
8,3 A
< 14,5 A (5)
2060.0013.XX 2,5
A / 125 V
190
0,79
67,5 A (1)
8,3 A
< 14,5 A (5)
2060.0014.XX 3
A / 125 V
190
1,1
67,5 A (1)
8,3 A
14,5 A (5)
2060.0048.XX 3,15 A / 125 V
190
1,1
67,5 A (1)
8,3 A
< 14,5 A (5)