Document Number: 23092
Revision 14-May-02
www.vishay.com
20
440L, 30LV, 30LVS, 25Y, 125L, 20VL Series
Vishay Cera-Mite
AC Line Rated Disc Capacitors
ceramite.support@vishay.com
PERFORMANCE DATA / SERIES: 440L 30LV 30LVS 25Y 125L 20VL
Application Voltage Range
250/500 300/400 250/400 250/400 250 250
(Vrms 50/60 Hz) (Note 1)
Dielectric Strength
4000 2500 2500 2500 2000 1250
(Vrms 50/60 H
Z
for 1 minute)
Dissipation Factor (Maximum)
Insulation Resistance (Minimum)
1000
F
Mechanical Data Service Temperature 125°C Maximum;
Coating Material per UL94V0
Temperature Characteristics
Y5U Y5U Y5U Y5S Y5V Y5V
See Part Number Detail for Temperature Characteristics
2%
AC LINE RATED CERAMIC CAPACITOR SPECIFICATIONS
Series / Recognition / Voltage 440L 30LV 30LVS 25Y 125L 20VL
Un
derwriters Laboratories Inc.: (Note 2)
UL 1414 Across-The-Line Across-The-Line Across-The-Line
—
—
—
—
UL 1414 Antenna Coupling Antenna-Coupling Antenna-Coupling
—
—
—
—
UL 1414 Line-By-Pass Line-By-Pass Line-By-Pass Line-By-Pass Line-By-Pass Line-By-Pass
—
UL 1414 Rated Voltage 250 VAC 250 VAC 250 VAC 250 VAC 250 VAC
—
Electromagnetic Interference Filters
EMI Filters EMI Filters EMI Filters EMI Filters
—
EMI Filters
UL1283 Rated Voltage 600 VAC 250 VAC 250 VAC 250 VAC
—
250 VAC
Canadian Standards Association:
CSA 22.2 No.1 Across-The-Line Across-The-Line Across-The-Line
—
—
—
—
CSA 22.2 No.1 Isolation Isolation Isolation Isolation Isolation Isolation
—
CSA 22.2 No. 1 Rated Voltage 250 VAC 250 VAC 250 VAC 250 VAC 125/250 VAC
—
CSA 22.2 No. 8 Line-to-Ground Capacitors
—
Line-To-Ground Line-To-Ground Line-To-Ground
—
Line-To-Ground
For Use in Certified EMI Filters
—
Certified EMI Filters Certified EMI Filters Certified EMI Filters
—
Certified EMI Filters
CSA 22.2 No. 8 Rated Voltage
—
400 VAC 400 VAC 400 VAC
—
250 VAC
European CENELEC Electronic Components Committee (CECC) EN 132 400 to Publication IEC 384-14 Table II, Edition 2:
IEC 384-14 Second Edition Subclass Y: (Note 3)
Y1 Y2 Y2 Y2 Y4
—
Subclass Y Voltage (Vrms 50-60 Hz) 500 VAC 300 VAC 250 VAC 250 VAC 125 VAC
Type of Insulation Bridged Double or Basic or Basic or Basic or Basic or
—
Reinforced Supplementary Supplementary Supplementary Supplementary
Peak Impulse Voltage Before Endurance Test 8 kV 5 kV 5 kV 5 kV 2.5 kV
—
IEC 384-14 Second Edition Subclass X: (Note 4)
X1 X1 X1 X1 X1 X2
Subclass X Voltage (Vrms 50-60 Hz) 400 VAC 400 VAC 400 VAC 400 VAC 400 VAC 400 VAC
Peak Impulse Voltage in Service 2.5 to 4.0 kV 2.5 to 4.0 kV 2.5 to 4.0 kV 2.5 to 4.0 kV 2.5 to 4.0 kV To 2.5 kV
Application High Pulse High Pulse High Pulse High Pulse High Pulse Gen. Purpose
Damp Heat, Steady State Recognition Code HKF - 25
°
C/ + 125
°
C/21 days
SAFETY AGENCY RECOGNITION AND EMI/RFI FILTERING SUBCLASS
Note 1
Voltage Ratings: All ratings are manufacturer
’
s
rating.
Part markings are governed by agency
rules and customer requirements.
Parts are marked 250 VAC unless otherwise
requested.
Note 2
UL1414 Across-The-Line, Antenna Coupling, and
Line-By-Pass Capacitors:
Across-The-Line
—
A capacitor connected
either across a supply circuit or between
one side of a supply circuit and a conductive
part that may be connected to earth ground.
Antenna-Coupling
—
A capacitor connected
from an antenna terminal to circuits within an
appliance.
Line-By-Pass
—
A capacitor connected between
one side of a supply circuit and an accessible
conductive part.
Note 3
IEC 384-14 Subclass Y Capacitors:
A capacitor of a type suitable for use in situations
where failure of the capacitor could lead to
danger of electric shock.
Class Y capacitors are divided into sub- classes
based on type of insulation bridged and voltage
ranges.
For definitions of basic, supplementary,
double and reinforced insulation, see IEC
Publication 536.
Subclass Y capacitors may be used in
applications which require a Subclass
X rating.
Note 4
IEC 384-14 Subclass X Capacitors:
A capacitor of a type suitable for use
in situations where failure of the capacitor
would not lead to danger of electric
shock.
Class X capacitors are divided into subclasses
according to the peak impulse test voltage
superimposed on the main voltage
Note 5
AC Leakage Current:
For all Series (except 125L) - AC Leakage
Current (mA) specified at 250 Vrms, 60 Hz.
For 125L Series - AC Leakage Current
(mA) specified at 125 Vrms, 60Hz.
Note 6
Alternate Lead Spacings of
7.5mm and 10mm
are available bulk or tape & reel.
European Required Minimum Lead Clearance
(Prevents Use of Inside Crimp) .315" (8mm) on
440L Series; 0.118" (3mm) on all other series.
X & Y EMI/RFI FILTER TYPES: ACROSS-THE-LINE,
LINE-BY-PASS, ANTENNA COUPLING
Vishay Cera-Mite AC Line Rated Discs are rugged, high voltage capacitors speci
fi
cally designed and tested
for use on 125 Volt through 600 Volt AC power sources. Certi
fi
ed to meet demanding X & Y type worldwide
safety agency requirements, they are applied in across-the-line, line-to-ground, and line-by-pass
fi
ltering applications. Vishay Cera-Mite offers the most
complete selection in the industry
—
six product families
—
exactly tailored to your needs.
Worldwide Safety Agency Recognition
- Underwriters Laboratories - UL1414 & UL1283
- Canadian Standards Association - CSA 22.2 No. 1 & No. 8
- European EN132400 to IEC 384-14 Second Edition
Required In AC Power Supply and Filter Applications
Six Families Tailored To Specific Industry Requirements
Complete Range of Capacitance Values