AD590–SPECIFICATIONS
Model
AD590J
AD590K
Min
Typ
Max
Min
Typ
Max
Units
ABSOLUTE MAXIMUM RATINGS
Forward Voltage ( E+ or E–)
+44
Volts
Reverse Voltage (E+ to E–)
–20
Volts
Breakdown Voltage (Case E+ or E–)
±200
Volts
Rated Performance Temperature Range
1
–55
+150
–55
+150
°C
Storage Temperature Range
1
–65
+155
–65
+155
°C
Lead Temperature (Soldering, 10 sec)
+300
°C
POWER SUPPLY
Operating Voltage Range
+4
+30
+4
+30
Volts
OUTPUT
Nominal Current Output @ +25
°C (298.2K)
298.2
A
Nominal Temperature Coefficient
1
A/K
Calibration Error @ +25
°C
5.0
2.5
°C
Absolute Error (Over Rated Performance Temperature Range)
Without External Calibration Adjustment
10
5.5
°C
With +25
°C Calibration Error Set to Zero
3.0
2.0
°C
Nonlinearity
1.5
0.8
°C
Repeatability
2
±0.1
°C
Long-Term Drift
3
±0.1
°C
Current Noise
40
pA/
√Hz
Power Supply Rejection
+4 V
≤ V
S
≤ +5 V
0.5
A/V
+5 V
≤ V
S ≤ +15 V
0.2
V/V
+15 V
≤ V
S
≤ +30 V
0.1
A/V
Case Isolation to Either Lead
10
Effective Shunt Capacitance
100
pF
Electrical Turn-On Time
20
s
Reverse Bias Leakage Current
4
(Reverse Voltage = 10 V)
10
pA
PACKAGE OPTIONS
TO-52 (H-03A)
AD590JH
AD590KH
Flatpack (F-2A)
AD590JF
AD590KF
NOTES
1The AD590 has been used at –100
°C and +200°C for short periods of measurement with no physical damage to the device. However, the absolute errors
specified apply to only the rated performance temperature range.
2Maximum deviation between +25
°C readings after temperature cycling between –55°C and +150°C; guaranteed not tested.
3Conditions: constant +5 V, constant +125
°C; guaranteed, not tested.
4Leakage current doubles every 10
°C.
Specifications subject to change without notice.
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels.
All min and max specifications are guaranteed, although only those shown in boldface are tested on all production units.
(@ +25 C and VS = +5 V unless otherwise noted)
–2–