FEATURES
This inlet-socket type EMC filter prevent microcomputer opera-
tional errors by use of a common mode choke coil featuring an
amorphous core with exceptional magnetic characteristics.
These plug-in type EMC filters provide highly effective attenua-
tion of high-voltage pulses power lines.
These small, high-performance IEC-type inlet sockets with inte-
gral EMC filters provide outstanding common-mode noise atten-
uation characteristics over a wide band of frequencies.
Current leakage is maintained at less than 0.4mA.
APPLICATIONS
Personal computers, computer terminals, office automation equip-
ment, digital applied devices (ECRs, electronic calculators, elec-
tronic scales, etc.), measurement devices, medical equipment, etc.
Particularly appropriate for various types of electronic devices that
require miniaturization.
SAFETY STANDARDS
The authorization standard is different depending on time when products were produced about European standards.
SHAPES AND DIMENSIONS
Typical dimensions for installation
Tighten the panel mounting M3 dia. bolt with the torque under 5.88X10–1Nm.
Dimensions in mm
Case: metal, input terminal: inlet-socket (EN60320), output terminal: Faston #250(t:0.8mm)
ELECTRICAL CHARACTERISTICS
Input pulse width: 0.4s
Part No.
Standard and standard No.
U.S.A
Canada
Europe
Produced before July, 2003
Produced after July, 2003
UL1283
CSA C22.2 No.8
VDE565 Teil3
EN133200
ZUB2203H-FS
E62388
LR76849C
R40030
P03200359
ZUB2206H-FS
E62388
LR76849C
R40030
P03200359
UL
CSA
TV
NEMKO
B
E
F
Ground terminal
Faston
G
D
A
H
C
From back side panel
From front panel
31.2
40
23.2
3.6
R5.5
30
40
21.5
3.6 or M3 tap
R3.5
Part No.
A
B
CDE
F
G
H
ZUB2203H-FS, 2206H-FS
48
60.3
25
40
38
5.2
30.5
3.3
Part No.
ZUB2203H-FS
ZUB2206H-FS
Rated voltage Eac(V)
250
Rated current(A)
3
6
Test voltage Eac(V)[Between terminal and ground terminal]
2000
Insulation resistance(M
)
[DC. 500V, 1min/between terminal and ground terminal]
100min.
Leakage current(mA)[250V 60Hz]
0.4max.
DC resistance(m
)
150max.
100max.
Operating temperature range(°C)[Including self-temperature rise]
–25 to +85
With derating over(°C)
55
Temperature rise(°C)
30max.
Attenuation frequency range
(MHz)[+5 to +35°C]
Differential mode at 30dB
2 to 300
3 to 300
Common mode at 30dB
1 to 300
3 to 300
Pulse attenuation characteristics
Input pulse voltage(kV)
Differential mode at 20dB
1.3
0.6
Common mode at 20dB
0.7
0.3
Weight(g)
48