參數(shù)資料
型號: Z0220516SSC
英文描述: Modem Controller
中文描述: 調(diào)制解調(diào)器控制器
文件頁數(shù): 39/48頁
文件大?。?/td> 1331K
代理商: Z0220516SSC
Z02202
ZiLOG
V.22bis Data Pump with Integrated AFE
PS000902-0501
Z02201
39
5. Set
TRNCTRL
, bits
0
2
(
TXCTRL
) to
1
(transmit
USB1).
6.
Inspect
TRNCTRL
, bit
6
(
S1DET
) and
TRNCTRL
, bit
7
(
SB1DET
) repeatedly for either a received
S1
signal or
SB1
. If
SB1
is received continuously for 270 msec,
proceed to step 12. If an
S1
signal is received
(
TRNCTRL
, bit
6
(
S1DET
) is
1
) wait for the
S1
to end.
7. Set
TRNCTRL
, bits
0
2
(
TXCTRL
) to
2
(transmit
S1
signal) for 100 msec.
8. Set
TRNCTRL
, bits
0
2
(
TXCTRL
) to
3
(
transmit
SB1
) for 350 msec.
9. Set
TRNCTRL
, bit
3
(
V22BIS
) to 1 (force 16-way
receive decisions). Wait for 150 msec.
10. Set
TRNCTRL
, bits
0
2
(
TXCTRL
) to
4
(
transmit
SB1
at 2400 bps). Wait for 200 msec.
11. Set
TRNCTRL
, bits
0
2
(
TXCTRL
) to
6
(2400 bps data
mode). Data is now being transmitted and received at
2400 bps.
12. If in step 6.,
SB1
is received instead of an S1 signal,
set
TRNCTRL
, bits
0
2
(
TXCTRL
) to
3
(
T
ransmit
SB1) for 765 msec. From that point, set
TRNCTRL
,
bits
0
2
(
TXCTRL
) to
5
(1200 bps
DATA
mode). Data
is now transmitted and received at 1200 bps.
MAKING A V.22BIS CONNECTION
In the following example, all timing is performed by the
host.
Originating Modem
1. Take the telephone line
OFF-HOOK
and dial.
2. Program the discrete tone detectors and the biquad
tone detectors for answer tones (2100 Hz) and call-
progress tones (200–600 Hz). Look for the answer
tone and call-progress tones (busy tones, ring back,
etc.)
3. Upon receiving the 2100 Hz answer tone, set
CONFIG
to
4008H
(V.22bis originate). After setting Config, the
host should be prepared to receive data from the
remote modem. The data pump holds the received data
to marks (that is, receives nothing) until the modem is
able to receive data from the remote modem.
4. When the data pump establishes a V.22bis connection,
and is ready to transmit data to the remote modem, it
sets Reg5, bit
1
(
CDET
) to 1. Data may now be
transmitted or received between the modems.
Answering Modem
1. Upon a ring signal or command from the terminal, take
the phone off-hook and transmit silence for 1.8–2.5
seconds.
2. If required, use the tone generators to transmit a 2100
Hz tone for 2.6–4 seconds. This tone is the V.25
answer tone.
3. Set
CONFIG
register, bits 0–6 (
MODE
) to
0
(
STANDBY
) and transmit silence for 75 msec.
4. Set
CONFIG
to
8
(
V.22BIS ANSWER
). After setting
Config, the host should be prepared to receive data
from the remote modem. The data pump holds the
received data to marks (that is, receives nothing) until
the modem is able to receive data from the remote
modem.
5. When the data pump establishes a V.22bis connection,
and is ready to transmit data to the remote modem, it
sets Reg5, bit
1
(
CDET
) to
1
. Data may now be
transmitted or received between the modems.
Notes:
1. The data pump sets Reg5, bit 1 (CDET) to 0 dur-
ing carrier dropouts, retrains, and when the re-
mote modem hangs up the telephone line.
Depending on the data mode, the host may use
Reg5, bit 1 (CDET), Reg5, bit 2 (RTRND), Dpc-
trl.EQE, EQMlev and EQMMaxThresh to determine
when the remote modem has initiated a retrain,
or has hung up the telephone line.
2. During 2400 bps V.22bis data mode, the host may
use Dpctrl.EQE and EQMMaxThresh or EQMlev, to
determine when to initiate a retrain (see Table
15, Mstatus.RETRAIN) to improve the quality of
the connection.
相關(guān)PDF資料
PDF描述
Z0220516SSC1961 Modem Controller
Z0220516SSCR3641 Modem Controller
Z0220516SSCR4259 Modem Controller
Z0220516SSCR4292 Modem Controller
Z0221500ZCO IC-MODEM EVALUATION KIT
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
Z0220516SSC1961 功能描述:電信線路管理 IC OTP CONTROLLER 86E34 RoHS:否 制造商:STMicroelectronics 產(chǎn)品:PHY 接口類型:UART 電源電壓-最大:18 V 電源電壓-最小:8 V 電源電流:30 mA 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:VFQFPN-48 封裝:Tray
Z0220516SSC1961TR 功能描述:IC MODEM CTRL 28SOIC RoHS:否 類別:集成電路 (IC) >> 接口 - 調(diào)制解調(diào)器 - IC 和模塊 系列:- 標(biāo)準(zhǔn)包裝:25 系列:- 數(shù)據(jù)格式:V.21,V.22,V.23,V.29,V.32,V.34,V.90,V.92,Bell 103,Bell 212A 波特率:33.6k 電源電壓:3.3V 安裝類型:- 封裝/外殼:- 供應(yīng)商設(shè)備封裝:- 包裝:托盤 配用:591-1013-ND - KIT DEV SOCKETMODEM PARALLEL591-1009-ND - KIT DEV SRL SOCKETMODEM UNIVERSL 其它名稱:MT5656SMI-P-V-34.R2-SPMT5656SMI-P-V-34.R2-SP-NDQ4711574
Z0220516SSCR3641 功能描述:電信線路管理 IC OTP CONTROLLER 86E34 RoHS:否 制造商:STMicroelectronics 產(chǎn)品:PHY 接口類型:UART 電源電壓-最大:18 V 電源電壓-最小:8 V 電源電流:30 mA 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:VFQFPN-48 封裝:Tray
Z0220516SSCR3641T 制造商:ZILOG 制造商全稱:ZILOG 功能描述:MODEM CONTROLLER IDEAL FOR LOW POWER CONSUMPTION, SMALL SIZE REQUIREMENTS
Z0220516SSCR3641TR 功能描述:IC MODEM CTRL 28SOIC RoHS:否 類別:集成電路 (IC) >> 接口 - 調(diào)制解調(diào)器 - IC 和模塊 系列:- 標(biāo)準(zhǔn)包裝:25 系列:- 數(shù)據(jù)格式:V.21,V.22,V.23,V.29,V.32,V.34,V.90,V.92,Bell 103,Bell 212A 波特率:33.6k 電源電壓:3.3V 安裝類型:- 封裝/外殼:- 供應(yīng)商設(shè)備封裝:- 包裝:托盤 配用:591-1013-ND - KIT DEV SOCKETMODEM PARALLEL591-1009-ND - KIT DEV SRL SOCKETMODEM UNIVERSL 其它名稱:MT5656SMI-P-V-34.R2-SPMT5656SMI-P-V-34.R2-SP-NDQ4711574