
XECOM
(13)
XE5620
XE5620 Modem Registers
S0
Answer on nth Ring:
S0 sets the modem to
automatically answer on the nth ring. Setting S0 to 0
disables automatic answer.
Range:
0 to 255
Units
Rings
Default
0
S1
Ring Count:
S1 is a read-only register showing the
number of rings detected. If a ring is not detected
within 8 seconds, S1 is reset to zero.
Range:
0 to 255
Units
Rings
Default
0
S2
Escape Character:
S2 determines the ASCII escape
character. Values of 0-127 select valid characters;
values from 128 to 255 disable the escape sequence.
Range:
0 to 255
Units
ASCII Character
Default
43 (+)
S3
Line Termination Character:
S3 determines the
ASCII character which will terminate commands and
modem responses.
Range:
0 to 127
Units
ASCII Character
Default
13 (Carriage Return)
S4
Line Feed Character:
S4 sets the ASCII character
to act as a line feed character in modem responses.
Range:
0 to 127
Units
ASCII Character
Default
10 (Line Feed)
S5
Backspace Character:
S5 defines the ASCII
character used as a backspace to edit the command
line.
Range:
0 to 127
Units
ASCII Character
Default
8 (Back Space)
S6
Dial Tone Wait Time:
S6 determines how long the
modem waits for dial tone before dialing. The Dial
Tone Wait Time cannot be set to less than two seconds.
Range:
Units
Default
3 to 7
Seconds
6
S7
Wait for Carrier after Dialing:
S7 determines how long
the modem waits for a valid carrier signal after dialing.
Range:
1 to 255
Units
Seconds
Default
60
S8
Comma Pause Time:
S8 defines the duration of the
pause initiated by a comma in the dialing string. The pause
is generally used when waiting for a second dial tone.
Range:
1 to 255
Units
Seconds
Default
2
S9
Carrier Detect Response Time:
S9 establishes the
length of time the remote modem's carrier must be present
to be recognized as valid.
Range:
1 to 255
Units
0.1 Seconds
Default
6
S10
Carrier Off Disconnect Delay
: S10 selects how long
carrier must be lost before the modem disconnects. Note:
If S10 is smaller than the value of S9 or S10 is set to 255,
the modem will not automatically disconnect on loss of
carrier.
Range:
1 to 255
Units
0.1 Seconds
Default
14
S11
Tone Dialing Speed:
S11 sets the duration and spacing
of the dialing tones. S11 does not affect the pulse dialing.
Range:
50 to 255
Units
1 Millisecond
Default
95
S12
Escape Code Guard Timer:
S12 sets the escape
sequence guard timer. If characters are received before or
after the escape sequence, within the guard timer, the
modem aborts the escape attempt and remains in data
mode.
Range:
0 to 255
Units
0.02 Seconds
Default
50
S13
Pulse Dialing :
S13 permits pulse dialing to be disabled
Register Setting
Function
0
No Pulse Dialing
1
Pulse Dialing Allowed