Spartan-II/Spartan-IIE Family OTP Configuration PROMs (XC17S00A)
DS078 (v1.10) June 25, 2007
Product Specification
6
R
AC Characteristics Over Operating Condition(1)
Symbol
Description
Min
Max
Units
TOE
RESET/OE to Data Delay
–
45
ns
TCE
CE to Data Delay
–
60
ns
TCAC
CLK to Data Delay
–
80
ns
TOH
Data Hold From CE, RESET/OE, or CLK(2)
0–
ns
TDF
CE or RESET/OE to Data Float Delay(2,3)
–50
ns
TCYC
Clock Periods
100
–
ns
TLC
CLK Low Time(2)
50
–
ns
THC
CLK High Time(2)
50
–
ns
TSCE
CE Setup Time to CLK (to guarantee proper counting)
25
–
ns
THCE
CE Hold Time to CLK (to guarantee proper counting)
0
–
ns
THOE
RESET/OE Hold Time (guarantees counters are reset)
25
–
ns
TCEH
CE High time (guarantees counters are reset)
20
–
ns
Notes:
1.
AC test load = 50 pF
2.
Guaranteed by design, not tested.
3.
Float delays are measured with 5 pF AC loads. Transition is measured at ±200 mV from steady state active levels.
4.
All AC parameters are measured with VIL = 0.0V and VIH = 3.0V.
5.
If TCEH High < 2μs, TCE = 2 μs.
6.
If THOE High < 2μs, TCE = 2 μs.
RESET/OE
CE
CLK
DATA
TCE
TOE
TLC
TSCE
THCE
THOE
TCAC
TOH
TDF
TOH
THC
DS030_03_111502
TCYC
TCEH