X9409 – Preliminary Information
Characteristics subject to change without notice.
11 of 21
REV 1.6 1/30/03
www.xicor.com
ABSOLUTE MAXIMUM RATINGS
Temperature under bias ....................–65°C to +135°C
Storage temperature.........................–65°C to +150°C
Voltage on SDA, SCL or any address
input with respect to V
SS
.........................–1V to +7V
V = |V
H
– V
L
|........................................................5V
Lead temperature (soldering, 10 seconds).........300°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification)
is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0
°
C
–40
°
C
Max.
+70
°
C
+85
°
C
Device
X9409
X9409-2.7
Supply Voltage (V
CC
) Limits
5V
±
10%
2.7V to 5.5V
ANALOG CHARACTERISTICS
(Over recommended operating conditions unless otherwise stated.)
Symbol
Parameter
Limits
Test Conditions
Min.
Typ.
Max.
±20
15
+3
150
V
CC
Unit
%
mW
mA
V
dBV
%
MI
(3)
MI
(3)
ppm/°C
ppm/°C
pF
μA
End to end resistance tolerance
Power rating
Wiper current
Wiper resistance
Voltage on any V
H
/R
H
or V
L
/R
L
pin
Noise
Resolution
(4)
Absolute linearity
(1)
Relative linearity
(2)
Temperature coefficient of R
TOTAL
Ratiometric temp. coefficient
Potentiometer capacitances
R
H
, R
L
, R
W
leakage current
25°C, each pot @5V, 2.5K
I
W
R
W
-3
50
I
W
=
±
3mA, V
CC
= 3V to 5V
V
SS
= 0V
Ref: 1kHz
V
TERM
V
SS
-120
1.6
-1
-0.2
+1
+0.2
V
w(n)(actual)
—V
w(n)(expected)
V
w(n + 1)
—[V
w(n) + MI
]
±
300
20
C
H
/C
L
/C
W
I
AL
10/10/25
0.1
See Macro Model
V
IN
= V
SS
to V
CC
. Device is
in stand-by mode.
10
Notes:
(1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used
as a potentiometer.
(2) Relative Linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a potenti-
ometer. It is a measure of the error in step size.
(3) MI = RTOT/63 or (V
H
—V
L