11
FN8190.4
October 13, 2009
Equivalent AC Load Circuit
DC Operating Characteristics (Over the recommended operating conditions unless otherwise specified.)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
ICC1
VCC Supply Current (active)
fSCK = 2MHz, SO = Open, Other Inputs = VSS
700
A
ICC2
VCC Supply Current (non-volatile write)
fSCK = 2MHz, SO = Open, Other Inputs = VSS
3mA
ISB
VCC Current (standby)
SCK = SI = VSS, Addr. = VSS, CS = VCC
3A
ILI
Input Leakage Current
VIN = VSS to VCC
10
A
ILO
Output Leakage Current
VOUT = VSS to VCC
10
A
VIH
Input HIGH Voltage
VCC x 0.7
VCC +0.5
V
VIL
Input LOW Voltage
–0.5
VCC x 0.1
V
VOL
Output LOW Voltage
IOL = 3mA
0.4
V
Endurance and Data Retention
PARAMETER
MIN.
UNIT
Minimum endurance
100,000
Data changes per bit per register
Data retention
100
years
Capacitance
SYMBOL
TEST
TYP.
UNIT
TEST CONDITION
COUT
Output capacitance (SO)
8
pF
VOUT = 0V
CIN
Input capacitance (A0, A1, SI, and SCK)
6
pF
VIN = 0V
Power-up Timing
Input pulse levels = VCC x 0.1 to VCC x 0.9; Input rise and fall times = 10ns; Input and output timing level = VCC x 0.5.
SYMBOL
PARAMETER
MIN.
MAX.
UNIT
tr VCC
VCC Power-up rate
0.2
50
V/ms
tPUR
Power-up to initiation of read operation
1
ms
tPUW
Power-up to initiation of write operation
5
ms
NOTES:
11. This parameter is not 100% tested.
12. tPUR and tPUW are the delays required from the time the (last) power supply (VCC-) is stable until the specific instruction can be issued. These
parameters are periodically sampled and not 100% tested.
5V
1533
Ω
100pF
SDA
OUTPUT
RH
10pF
CL
RW
RTOTAL
CW
25pF
10pF
RL
SPICE MACRO MODEL
X9401