X4043/45
Characteristics subject to change without notice.
14 of 25
REV 1.1.17 9/14/01
www.xicor.com
ABSOLUTE MAXIMUM RATINGS
Temperature under bias ................... -65°C to +135°C
Storage temperature ........................ -65°C to +150°C
Voltage on any pin with
respect to V
SS
.......................................-1.0V to +7V
D.C. output current ...............................................5mA
Lead temperature (soldering, 10 seconds)........ 300°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; the functional operation of
the device (at these or any other conditions above those
listed in the operational sections of this specification) is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
-40°C
Max.
70°C
+85°C
Option
–2.7 and –2.7A
Blank and –4.5A
Supply Voltage Limits
2.7V to 5.5V
4.5V to 5.5V
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified.)
Notes:
(1) The device enters the active state after any start, and remains active until: 9 clock cycles later if the device select bits in the slave
address byte are incorrect; 200ns after a stop ending a read operation; or t
WC
after a stop ending a write operation.
(2) The device goes into standby: 200ns after any stop, except those that initiate a nonvolatile write cycle; t
WC
after a stop that initiates
a nonvolatile cycle; or 9 clock cycles after any start that is not followed by the correct device select bits in the slave address byte.
(3) V
IL
min. and V
IH
max. are for reference only and are not tested.
Symbol
I
CC1
(1)
I
CC2
(1)
I
SB1
(2)
Parameter
V
CC
= 2.7 to 5.5V
Min.
Unit
mA
mA
μA
Test Conditions
V
IL
= V
CC
x 0.1, V
IH
= V
CC
x 0.9
f
SCL
= 400kHz
Max.
1.0
3.0
1
Active supply current read
Active supply current write
Standby current AC (WDT off)
V
IL
= V
CC
x 0.1, V
IH
= V
CC
x 0.9
f
SCL
= 400kHz, SDA = open
V
CC
= 1.22 x V
CC
min
V
SDA
= V
SCL
= V
SB
Others = GND or V
SB
V
SDA
=V
SCL
= V
SB
Others = GND or V
SB
V
IN
= GND to V
CC
V
SDA
= GND to V
CC
device is in standby
I
SB2
(2)
Standby current DC (WDT off)
1
μA
I
SB3
(2)
Standby current DC (WDT on)
20
μA
I
LI
I
LO
Input leakage current
Output leakage current
10
10
μA
μA
V
IL
(3)
V
IH
(3)
V
HYS
Input LOW voltage
Input nonvolatile
Schmitt trigger input hysteresis
Fixed input level
V
CC
related level
Output LOW voltage
-0.5
V
CC
x 0.3
V
CC
+ 0.5
V
V
V
CC
x 0.7
0.2
.05 x V
CC
V
V
V
V
OL
0.4
I
OL
= 3.0mA (2.7–5.5V)
I
OL
= 1.8mA (2.0–3.6V)