X25330
8
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias....................–65
Storage Temperature........................–65
Voltage on any Pin with Respect
to V
SS
.........................................................–1V to +7V
D.C. Output Current ............................................. 5mA
(Soldering, 10 seconds) ..............................300
°
°
C to +135
C to +150
°
°
C
C
°
C
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified.)
7037 FRM T08
POWER-UP TIMING
7037 FRM T09
CAPACITANCE
Symbol
C
I/O(3)
C
IN(3)
T
A
= +25
°
C, f = 1MHz, V
CC
= 5V
7037 FRM T10
Notes:
(1) V
(2) This parameter is periodically sampled and not 100% tested.
(3) t
PUR
and t
PUW
are the delays required from the time V
parameters are periodically sampled and not 100% tested.
IL
min. and V
IH
max. are for reference only and are not tested.
CC
is stable until the specified operation can be initiated. These
Symbol
I
CC
I
SB
I
LI
I
LO
V
IL(1)
V
IH(1)
V
OL1
V
OH1
V
OL2
V
OH2
Parameter
Limits
Units
mA
μ
A
μ
A
μ
A
V
V
V
V
V
V
Test Conditions
x 0.1/V
CC
CC
, V
IN
=
V
SS
or V
CC
– 0.3V
V
IN
=
V
SS
to V
CC
V
OUT
=
V
SS
to V
CC
Min.
Max.
5
1
10
10
V
CC
x 0.3
V
CC
+ 0.5
0.4
0.4
V
V
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
CC
Supply Current (Active)
Supply Current (Standby)
SCK = V
CS
= V
CC
x 0.9 @ 5MHz,
CC
–1
V
CC
x 0.7
I
OL
= 3mA, V
CC
= 5V
I
OH
= –1.6mA, V
CC
= 5V
I
OL
= 1.5mA, V
CC
= 3V
I
OH
= –0.4mA, V
CC
= 3V
V
CC
–0.8
V
CC
–0.3
Symbol
T
PUR(3)
T
PUW(3)
Parameter
Min.
Max.
1
1
Units
ms
ms
Power-up to Read Operation
Power-up to Write Operation
Parameter
Max.
8
6
Units
pF
pF
Test Conditions
V
I/O
= 0V
V
IN
= 0V
Output Capacitance (SO)
Input Capacitance (SCK, SI,
CS
,
WP
,
HOLD
)
RECOMMENDED OPERATING CONDITIONS
7037 FRM T06
Temperature
Commercial
Industrial
Min.
0
°
C
–40
°
C
Max.
+70
°
C
+85
°
C
7037 FRM T07
Supply Voltage
X25330
X25330-2.5
Limits
5V
±
10%
2.5V to 5.5V
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
those indicated in the operational sections of this
specification is not implied. Exposure to absolute