X25041
8
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
listed in the operational sections of this specification is not
implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias .................. –65
°
C to +135
°
C
Storage Temperature ....................... –65
°
C to +150
°
C
Voltage on any Pin with Respect to V
SS.........
–1V to +7V
D.C. Output Current .............................................5mA
Lead Temperature
(Soldering, 10 seconds).............................. 300
°
C
CAPACITANCE
T
A
= +25
°
C, f = 1MHz, V
CC
= 5V.
Symbol
C
OUT(2)
Output Capacitance (SO)
C
IN(2)
Input Capacitance (SCK, SI,
CS
,
WP
,
HOLD
)
Test
Max.
8
6
Units
pF
pF
Conditions
V
OUT
= 0V
V
IN
= 0V
6556 PGM T09
RECOMMENDED OPERATING CONDITIONS
Temp
Commercial
Industrial
Military
Min.
0
°
C
–40
°
C
–55
°
C
Max.
+70
°
C
+85
°
C
+125
°
C
6556 PGM T05
Supply Voltage
X25041
X25041-3
X25041-2.7
Limits
5V
±
10%
3V to 5.5V
2.7 to 5.5V
6556 PGM T06
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified.)
Limits
Symbol
I
CC
Parameter
V
CC
Supply Current (Active)
Min.
Max.
3
Units
mA
Test Conditions
SCK = V
CC
x 0.1/V
CC
x 0.9 @ 1MHz,
SO = Open
CS
= V
CC
,
V
IN
= V
SS
or V
CC
– 0.3V
V
IN
= V
SS
to V
CC
V
OUT
= V
SS
to V
CC
I
SB
I
LI
I
LO
V
IL(1)
V
IH(1)
V
OL
V
OH
V
CC
Supply Current (Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
150
10
10
μ
A
μ
A
μ
A
V
V
V
V
–1
V
CC
x 0.3
V
CC
x 0.7 V
CC
+ 0.5
0.4
I
OL
= 2mA
I
OH
= –1mA
V
CC
–0.8
6556 PGM T07.1
POWER-UP TIMING
Symbol
t
PUR(2)
t
PUW(2)
Parameter
Min.
Max.
1
Units
ms
Power-up to Read Operation
Power-up to Write Operation
5
ms
6556 PGM T08
Notes:
(1) V
IL
min. and V
IH
max. are for reference only and are not tested.
(2) This parameter is periodically sampled and not 100% tested.