8
X24C01
Supply Voltage
Limits
X24C01
X24C01-3.5
X24C01-3
X24C01-2.7
4.5V to 5.5V
3.5V to 5.5V
3.0V to 5.5V
2.7V to 5.5V
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias.................. –65
°
C to +135
°
C
Storage Temperature ....................... –65
°
C to +150
°
C
Voltage on any Pin with
Respect to V
SS
............................ –1.0V to +7.0V
D.C. Output Current ............................................5 mA
Lead Temperature
(Soldering, 10 Seconds) ............................. 300
°
C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
0
°
C
–40
°
C
–55
°
C
Max.
70
°
C
+85
°
C
+125
°
C
Commercial
Industrial
Military
D.C. OPERATING CHARACTERISTICS
(Over recommended operating conditions, unless otherwise specified)
Limits
Symbol
I
CC(1)
I
CC(2)
I
SB1(1)
Parameter
Min.
Max.
1
2
100
Units
mA
Test Conditions
V
CC
Supply Current (Read)
V
CC
Supply Current (Write)
V
CC
Standby Current
SCL = V
CC
x 0.1/V
CC
x 0.9 Levels
@ 100 KHz, SDA = Open
SCL = SDA = V
CC
,
V
CC
= 5V
±
10%
SCL = SDA = V
CC
, V
CC
= 2.7V
V
IN
= GND to V
CC
V
OUT
= GND to V
CC
μ
A
I
SB2(1)
I
LI
I
V
lL(2)
V
IH(2)
V
OL
V
CC
Standby Current
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
50
10
10
μ
A
μ
A
μ
A
V
V
V
–1.0
V
CC
x 0.3
V
CC
x 0.7 V
CC
+ 0.5
0.4
I
OL
= 2.1 mA
3837 PGM T03
CAPACITANCE
T
A
= 25
°
C, f = 1.0 MHz, V
CC
= 5V
Symbol
Parameter
Max.
Units
Test Conditions
C
I/O(3)
C
IN(3)
Input/Output Capacitance (SDA)
Input Capacitance (SCL)
8
6
pF
pF
V
I/O
= 0V
V
IN
= 0V
3837 PGM T05
Notes:
(1) Must perform a stop command prior to measurement.
(2) V
IL
min. and V
IH
max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.