ASIC
SerDes/PHY
Tx Rx timer
Rx CDR
Control &
data management
2 wire
interface
30-pin edge
connector
XFI
9.95-11.08 Gbit/s
Vcc
Hot swap control
Laser
10 G
laser
9.95-11.08
Gbit/s
PIN + TIA/LA
XFP transceiver block diagram
XFP transceiver mechanical package [mm]
Ordering code
V23833-F0005-B101
V23833-F0105-B001
Wave length
850 nm
1310 nm
Optical connect
LC
LC
Reach
300 m*
10 km
Ordering code
V23833-F9909-Z001
a
Product
XFP evaluation board kit
Description
Test board with 30-Pin XFP connector and cage
Products
Accessories
* Using 50 μm multi-mode fiber with 2000 MHz*km bandwidth
For more information, please contact:
Infineon Technologies
North America (CA):
Irene Yan
Phone: +1-408-501-5664
irene.yan@infineon.com
Europe (Germany):
Angela Scholl
Phone: +49-30-386-22521
angela.scholl@infineon.com
Asia (Hong Kong):
Owen Chui
Phone: +852-2832-048
owen.chui@infineon.com
Japan (Tokyo):
Kunikazu Watanabe
Phone: +81-3-5449-6705
kunikazu.watanabe@infineon.com
Edition September 2003
Published by Infineon Technologies AG,
St.-Martin-Strae 53,
D-81669 München
Infineon Technologies AG 2003.
All Rights Reserved.
Please note:
The information herein describes certain components and shall
not be considered as a guarantee of characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not
limited to warranties of non-infringement regarding circuits,
descriptions and charts stated herein.
Infineon Technologies is an approved CECC manufacturer.
Information
For further information on technology, delivery terms and
conditions and prices, please contact your nearest Infineon
Technologies office in Germany or our Infineon Technologies
representatives worldwide (www.infineon.com).
Warnings
Due to technical requirements, components may contain dangerous substances.
For information on the types in question please contact your nearest Infineon
Technologies office.
Infineon Technologies components may only be used in life-support devices
or systems with the express written approval of Infineon Technologies if a
failure of such components can reasonably be expected to cause the failure
of that life-support device or system, or to affect the safety or effectiveness
of that device or system. Life-support devices or systems are intended to be
implanted in the human body, or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to assume that the
health of the user or other persons may be endangered.
Order no. B159-H8165-G1-X-7600
Printed in Germany
PS 09032.
Z