8
Siemens AG
Small relay D2
General data
Typical operate time at U
nom
and at 20 °C
Typical reverse time at U
nom
and at 20 °C
Typical release time without/with diode in parallel
Typical bounce time
Maximum switching rate without load
Ambient temperature according to DIN IEC 255
Part 1-00 or VDE 0435 part 201
Vibration resistance,
Frequency range according to IEC 68-2-6
Shock resistance, half sinus, 11 ms according to
IEC 68-2-27
Protection class according to DIN VDE 0470
part 1 / IEC 529
Mechanical endurance
Mounting position
Processing information
Weight
Electrical endurance
Contact material silver, gold-plated, against palladium silver (-B101)
Switching voltage
V
0
6–
24–
Contact material palladium silver, gold-plated, against palladium silver (-B201)
Switching voltage
V
mA
0
0
6–
100
24–
50
60–
50
3 ms
3 ms
2 ms / 4 ms
3 ms
100 operations/s
-40 °C ... +85 °C
50 g
10 - 500 Hz
50 g
immersion cleanable
sealing corresponds to DIN IEC 68, part 2-17, method Qc 2
2 x 10
7
switching cycles
any
Ultrasonic cleaning is not recommended
approx. 5 g
Switching current
mA
0
100
50
Switching cycles
Load type
Endurance determined
by switching cycles
10
10
10
approx. 2 x 10
7
approx. 2 x 10
7
approx. 2 x 10
7
dry circuit
resistive
resistive
Switching current
Switching cycles
Load type
Endurance determined
by switching cycles
10
10
10
10
approx. 2 x 10
7
approx. 2 x 10
7
approx. 2 x 10
7
approx. 10
7
dry circuit
resistive
resistive
resistive
with 10 m cable
Insulation
Insulation's resistance at 500 V
Dielectric test voltage (1 min)
Contact / winding at 1 winding / at 2 windings
Changeover contact / changeover contact
Changeover tip / changeover tip
1000 M
1500 V~
eff
/ 1000 V~
eff
1500 V~
eff
1000 V~
eff