Specifications are subject to change without notice UDM35DS 040706
1
Multi-input modular instrument 3 1/2 dgt LED
0.1% RDG basic accuracy
TRMS AC current and voltage measurements
AC/DC current measurements: selectable full scales
(200μA to 5A)
AC/DC voltage measurements: selectable full scales
(200mV to 500V)
°C or °F temperature measurements
(Pt100-250-500-1000, Ni100, TC J-K-S-T-E)
Resistance measurements: selectable full scales
(20
to 20k
)
Up to 4 independent alarm set-points (optional)
20mA/10VDC analog output (optional)
Serial port RS485 or RS232 (optional)
MODBUS, JBUS communication protocol
Product Description
μp-based
meter, 3 1/2 dgt LED indica-
tor, for current, voltage, tem-
perature
and
measurements.
ranges and functions easily
programmable from the key-
pad or from the PC by
digital
panel
resistance
Measuring
means of optional UdmSoft
software. UDM
35
includes
storage min-max functions
and double level protection
password.
Housing
panel mounting with front
protection
degree:
NEMA4x.
for
IP67,
Type UDM35
Type Selection
Slot A (measuring inputs)
LSX:
signal inputs:
0.2-2-20mA DC/AC;
0.2-2-20V DC/AC
LSE/
LSF:
signal inputs + AUX:
0.2-2-20mA DC/AC;
0.2-2-20V DC/AC
signal inputs:
0.2-2-5A DC/AC;
20-200-500V DC/AC
signal inputs: TC tem-
perature probes (J-K-S-
T-E, Pt100-250-500-
1000) and resistance
(0.02-0.2-2-20k
)
HSX:
TRX:
Slot B (communication)
XX:
SX:
SY:
AV (*):
Single analogue output,
0 to 20mA DC and
0 to 10V DC
None
Serial port RS485
Serial port RS232
Slot D (power supply)
H:
L:
90 to 260V AC/DC
18
to
60V AC/DC
Options
XX:
TX:
None
Tropicalization
Model
Slot A
Slot B
Slot C
Slot D
Options
How to order
How to order
UDM35 XXX XX XX X XX
Analogue inputs
BQ LSX module
BQ LSE/BQ LSF module
BQ HSX module
BQ TRX module
BQ TRX module
Digital inputs
Number of inputs
Use
Channels and variable
1, mA and V DC/AC
1, mA and V DC/AC + AUX
1,
A and V DC/AC
1, temperature
1, resistance
Incl. in the measuring module
1 (voltage-free)
key-pad lock
Display hold
Reset of latch alarms
Contact reading signal
BQ xxx: <0.1mA, <3,5V DC
BQ LSE/BQ LSF: <2.5mA,
<14V DC
Max 1k
Min 500k
Non-insulated
See table “Measuring
accuracy”, temperature drifts
and minimum-maximum
indications”
Close contact resistance
Open contact resistance
Insulation
Accuracy
(display,RS485)
Input Specifications
Front protection degree: IP67, NEMA4x
UdmSoft-kit
UdmSoft-kit: software plus “UCOM1” communication cable for
programming UDM
35
by means of PC.
Modular Indicator and Controller
Digital Panel Meters
Slot C (communication and alarm)
XX:
R1:
None
single relay output,
(AC1-8AAC, 250VAC)
Dual relay output,
(AC1-8AAC, 250VAC)
Dual relay output
(AC1-
8AAC, 250VAC)
+ dual
open collector output
(NPN, 100mA)
4 relay outputs
(AC1-5AAC, 250VAC)
AV(*):
Single analogue output,
0 to 20mA DC and
0 to 10V DC
R2:
R4:
R5:
(*):
The two analogue
outputs cannot be
used at the same
time. It is possible to
plug in only one
module by instru-
ment.