SLUS482B - APRIL 2001 REVISED DECEMBER 2004
2
www.ti.com
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage, VCC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gate drive current, continuous
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gate drive current
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, CAI, MOUT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, PKLMT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, VSENSE, OVP/EN, VAI
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input current, RT, IAC, PKLMT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum negative voltage, DRVOUT, PKLMT, MOUT
Power dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 V
0.2 A
1.2 A
8 V
5 V
10 V
10 mA
0.5 V
1 W
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
AVAILABLE OPTIONS
TJ
PACKAGE DEVICES
DW PACKAGE
UCC3819DW
D PACKAGE
UCC3819D
N PACKAGE
UCC3819N
PW PACKAGE
UCC3819PW
0
°
C to 70
°
C
40
°
C to 85
°
C
The D, DW, and PW packages are available taped and reeled. Add TR suffix to device type (e.g. UCC3819DTR) to
order quantities of 2500 devices per reel.
UCC2819D
UCC2819DW
UCC2819N
UCC2819PW
electrical characteristics
, T
A
= 0
°
C to 70
°
C for the UCC3819, 40
°
C to 85
°
C for the UCC2819, VCC = 12 V,
R
T
= 22 k
, C
T
= 270 pF, (unless otherwise noted)
supply current
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
μ
A
mA
Supply current, off
VCC = (VCC turnon threshold 0.3 V)
150
300
Supply current, on
VCC = 12 V,
No load on DRVOUT
2
4
6
UVLO
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
VCC turnon threshold
9.7
10.2
10.8
V
VCC turnoff threshold
9.4
9.7
V
UVLO hysteresis
0.3
0.5
V
voltage amplifier
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
VIO
VAOUT = 2.75 V,
VCM = 3.75 V
15
15
mV
VAI bias current
VAOUT = 2.75 V,
VCM = 3.75 V
50
200
nA
VSENSE bias current
CMRR
VSENSE = VREF,
VAOUT = 2.5 V
50
200
nA
VCM = 1 V to 7.5 V
50
70
dB
Open loop gain
VAOUT = 2 V to 5 V
IL = 150
μ
A
IL = 150
μ
A
50
90
dB
High-level output voltage
5.3
5.5
5.6
V
Low-level output voltage
0
50
150
mV