UC3842B, UC3843B, UC2842B, UC2843B, NCV3843BV
http://onsemi.com
3
ELECTRICAL CHARACTERISTICS
(V
CC
= 15 V [Note 4], R
T
= 10 k, C
T
= 3.3 nF. For typical values T
A
= 25
°
C, for min/max values
T
A
is the operating ambient temperature range that applies [Note 5], unless otherwise noted.)
UC284XB
UC384XB, XBV
Characteristics
Symbol
Min
Typ
Max
Min
Typ
Max
Unit
ERROR AMPLIFIER SECTION
Voltage Feedback Input (V
O
= 2.5 V)
V
FB
2.45
2.5
2.55
2.42
2.5
2.58
V
Input Bias Current (V
FB
= 5.0 V)
I
IB
–
– 0.1
–1.0
–
– 0.1
– 2.0
μ
A
Open Loop Voltage Gain (V
O
= 2.0 V to 4.0 V)
A
VOL
65
90
–
65
90
–
dB
Unity Gain Bandwidth (T
J
= 25
°
C)
BW
0.7
1.0
–
0.7
1.0
–
MHz
Power Supply Rejection Ratio (V
CC
= 12 V to 25 V)
PSRR
60
70
–
60
70
–
dB
Output Current
Sink (V
O
= 1.1 V, V
FB
= 2.7 V)
Source (V
O
= 5.0 V, V
FB
= 2.3 V)
I
Sink
I
Source
2.0
– 0.5
12
–1.0
–
–
2.0
– 0.5
12
–1.0
–
–
mA
Output Voltage Swing
High State (R
L
= 15 k to ground, V
FB
= 2.3 V)
Low State (R
L
= 15 k to V
ref
, V
FB
= 2.7 V)
(UC284XB, UC384XB)
(UC384XBV)
V
OH
V
OL
5.0
–
–
6.2
0.8
–
–
1.1
–
5.0
–
–
6.2
0.8
0.8
–
1.1
1.2
V
CURRENT SENSE SECTION
Current Sense Input Voltage Gain (Notes 6 & 7)
(UC284XB, UC384XB)
(UC384XBV)
A
V
2.85
–
3.0
–
3.15
–
2.85
2.85
3.0
3.0
3.15
3.25
V/V
Maximum Current Sense Input Threshold (Note 6)
(UC284XB, UC384XB)
(UC384XBV)
V
th
0.9
–
1.0
–
1.1
–
0.9
0.85
1.0
1.0
1.1
1.1
V
Power Supply Rejection Ratio (V
CC
= 12 V to 25 V, Note 6)
PSRR
–
70
–
–
70
–
dB
Input Bias Current
I
IB
–
– 2.0
–10
–
– 2.0
–10
μ
A
Propagation Delay (Current Sense Input to Output)
t
PLH(In/Out)
–
150
300
–
150
300
ns
OUTPUT SECTION
Output Voltage
Low State (I
Sink
= 20 mA)
(I
Sink
= 200 mA)
(UC284XB, UC384XB)
(UC384XBV)
(UC284XB, UC384XB)
(UC384XBV)
High State
(I
Source
= 20 mA)
(I
Source
= 200 mA)
V
OL
V
OH
–
–
–
13
–
12
0.1
1.6
–
13.5
–
13.4
0.4
2.2
–
–
–
–
–
–
–
13
12.9
12
0.1
1.6
1.6
13.5
13.5
13.4
0.4
2.2
2.3
–
–
–
V
Output Voltage with UVLO Activated (V
CC
= 6.0 V, I
Sink
= 1.0 mA)
V
OL(UVLO)
–
0.1
1.1
–
0.1
1.1
V
Output Voltage Rise Time (C
L
= 1.0 nF, T
J
= 25
°
C)
t
r
–
50
150
–
50
150
ns
Output Voltage Fall Time (C
L
= 1.0 nF, T
J
= 25
°
C)
t
f
–
50
150
–
50
150
ns
UNDERVOLTAGE LOCKOUT SECTION
Startup Threshold (V
CC
)
UCX842B, BV
UCX843B, BV
V
th
15
7.8
16
8.4
17
9.0
14.5
7.8
16
8.4
17.5
9.0
V
Minimum Operating Voltage After Turn–On (V
CC
)
UCX842B, BV
UCX843B, BV
V
CC(min)
9.0
7.0
10
7.6
11
8.2
8.5
7.0
10
7.6
11.5
8.2
V
4. Adjust V
above the Startup threshold before setting to 15 V.
5. Low duty cycle pulse techniques are used during test to maintain junction temperature as close to ambient as possible.
T
low
= 0
°
C for UC3842B, UC3843B; –25
°
C for UC2842B, UC2843B; –40
°
C for UC3842BV, UC3843BV
T
= +70
°
C for UC3842B, UC3843B; +85
°
C for UC2842B, UC2843B; +105
°
C for UC3842BV, UC3843BV
NCV3843BV: T
low
= –40
°
C, T
high
= +125
°
C. Guaranteed by design. NCV prefix is for automotive and other applications requiring site and
change control.
6. This parameter is measured at the latch trip point with V
FB
= 0 V.
7. Comparator gain is defined as: A
V
V Current Sense Input
V Output Compensation