UNITRODE CORPORATION
7 CONTINENTAL BLVD.
MERRIMACK, NH 03054
TEL. (603) 424-2410
FAX (603) 424-3460
UC1842/3/4/5
UC2842/3/4/5
UC3842/3/4/5
OFFLINE FLYBACK REGULATOR
SLOPE COMPENSATION
A fraction of the oscillator ramp can be resistively
summed with the current sense signal to provide slope
compensation for converters requiring duty cycles over
50%.
Note that capacitor, C forms a filter with R2 to suppress
the leading edge switch spikes.
Power Supply Specifications
1. Input Voltage
95VAC to 130VA
(50 Hz/60Hz)
3750V
40kHz
70%
2. Line Isolation
3. Switching Frequency
4. Efficiency @ Full Load
5. Output Voltage:
A. +5V,
±
5%; 1A to 4A load
Ripple voltage: 50mV P-P Max
B. +12V,
±
3%; 0.1A to 0.3A load
Ripple voltage: 100mV P-P Max
C. -12V ,
±
3%; 0.1A to 0.3A load
Ripple voltage: 100mV P-P Max
7