We reserve the right to make modifications and no guarantee of the accuracy of information contained is given.
Pepperl+Fuchs GmbH · 68301 Mannheim · Telephone (06 21) 7 76-0 · Telefax (06 21) 7 76-10 00 · Internet http://www.pepperl-fuchs.com
Copyright by Pepperl+Fuchs, Printed in Germany
100
F A C T O R Y A U T O M A T I O N
D
8
8
5.
A
1
-> , A
2
-> :*
)
8
object detected: switching output closed
no object detected: switching output open
Programming device
UB-PROG1
- for sensors UB 500/2000/4000/
6000-30GM-E0/E2-V15
- easy teach-in of the switching
points A1/A2 or measurement
window
- easy teach-in of the output
function:
window operation, normally-
open / normally-closed
function
one switch point, normally-
open / normally-closed
function
monitoring of the detection
range
For the teach-in procedure, the device
can be switched between V15 cable
connection outlet and V15 connector on
the sensor.
With the two pushbuttons A1 and A2, the
switching points/measurement win-
dow and the output function are to be set
according to the given table at the right.
The set switching points and functions
remain after removal of the pro-
gramming device and/or after swit-
A1
A2
A2
A1
A1
Output functions
Teach-in
1.
A
1
< A
2
: normally-open function
2.
A
2
< A
1
: normally-closed function
3.
A
1
-> :*
)
normally-open function
4.
A
2
-> :*
)
normally-closed function
Object clearance
8
Window
- no object in the acquisition
range*
)
- press pushbuton A1 1s
- press pushbutton A2 1s
*
)
A1 ->
teach-in.
Either all objects will be removed from the acquisition range or
the sound converter on the sensor is covered with the hand. In this way, the
converter must be deactivated.
or A2 -> means that the sonic beam cannot detect an object during
8
Display during teach-in
Object known
No object known
Object unsure (teach-in not valid)
LED green
Flashing
Flashing
Off
LED red LED yellow
Off
Off
Flashing
Off
On
Off
8
Monitoring
of the
acquisition
range
- target near switching point
- press pushbutton A1 1s
- target far from switching
point
- press pushbutton A2 1s
- target near switching point
- press pushbutton A2 1s
- target far from switching
point
- press pushbutton A1 1s
- target near switching point
- press pushbutton A2 1s
- no object in the acquisition
range*
)
- Press pushbutton A1 1s
- target near switching point
- press pushbutton A1 1s
- no object in the acquisition
range*
)
- press pushbutton A2 1s
V15 - Cable outlet
6
Sensor
Cable length: 2 m
1.A1 < A2
2.A2 < A1
3.A1
→
4.A2
→
5.A1
→
A2
→
8
8
8
8
Programming Device
UB - PROG 1
A2
39
22
6
S witching
on point