U62256A
April 20, 2004
3
Characteristics
All voltages are referenced to V
SS
= 0 V (ground).
All characteristics are valid in the power supply voltage range and in the operating temperature range specified.
Dynamic measurements are based on a rise and fall time of
≤
5 ns, measured between 10 % and 90 % of V
I
, as well as
input levels of V
IL
= 0 V and V
IH
= 3 V. The timing reference level of all input and output signals is 1.5 V,
with the exception of the t
dis
-times and t
en
-times, in which cases transition is measured ±200 mV from steady-state voltage.
a
Stresses greater than those listed under Absolute Maximum Ratings“ may cause permanent damage to the device. This is a stress rating only,
and functional operation of the device at condition above those indicated in the operational sections of this specification is not implied. Exposure
to absolute maximum rating conditions for extended periods may affect reliability
b
Maximum voltage is 7 V
c
Not more than 1 output should be shorted at the same time. Duration of the short circuit should not exceed 30 s.
Absolute Maximum Ratings
a
Symbol
Min.
Max.
Unit
Power Supply Voltage
V
CC
-0.5
7
V
Input Voltage
V
I
-0.5
V
CC
+ 0.5
b
V
Output Voltage
V
O
-0.5
V
CC
+ 0.5
b
V
Power Dissipation
P
D
-
1
W
Operating Temperature
C-Type
K-Type
A-Type
T
a
0
-40
-40
70
85
125
°
C
Storage Temperature
C/K-Type
A-Type
T
stg
-65
-65
125
150
°
C
Output Short-Circuit Current
at V
CC
= 5 V and V
O
= 0 V
c
| I
OS
|
200
mA
d
-2 V at Pulse Width 10 ns
Recommended
Operating Conditions
Symbol
Conditions
Min.
Max.
Unit
Power Supply Voltage
V
CC
4.5
5.5
V
Input Low Voltage
d
V
IL
-0.3
0.8
V
Input High Voltage
V
IH
2.2
V
CC
+ 0.3
V