http://www.tracopower.com
Page 3
All specifications valid at nominal input voltage, full load and +25
°
C after warm-up time unless otherwise stated.
General Specifications
Temperature ranges
–
Operating
–
25
°
C
…
+70
°
C ambient temp. max.
2% /
°
C
–
25
°
C
…
+ 85
°
C
–
Derating above 60
°
C
–
Storage (non operating)
Humidity
(non condensing)
95 % rel H max.
Temperature coefficient
0.02 % /
°
C
Switching frequency
80 kHz typ.
(Pulswidth modulation)
Efficiency
–
TSL 030 ... TSL 120
–
TSL 240
–
TSL 480
85 % typ.
90 % typ.
88 % typ.
Isolation
according to EN 60950, UL 1950, UL 508C
Reliability, calculated MTBF
(MIL-HDBK-217E)
–
TSL 030/ 060
–
TSL 120/ 240
–
TSL 480
516000 h @ 35
°
C /500000 h @ 35
°
C
447000 h @ 35
°
C /365000 h @ 35
°
C
287000 h @ 35
°
C
Safety standards
IEC 60950, EN 60950 (SELV),
UL/cUL 1950, UL 508C
Safety approvals
UL/cUL 1950 recognized, File E181381
UL 508 C listed, File E210002
CB-Scheme
Electromagnetic compatibility (EMC), Emissions
–
Conducted RI suppression
EN 50081-1 / EN 50081-2
EN 55011 class B, EN 55022 class B,
FCC part 15, level B
120W
–
480W models with option P
–
Harmonic current emissions (PFHC)
EN 61000-3-2, Class A
EN 61000-3-2, Class D
(50%
–
100% load)
Electromagnetic compatibility (EMC), Immunity
–
Electrostatic discharge (ESD)
–
Radiated RF field immunity
–
Electrical fast transient / burst immunity
–
Surge immunity
–
Immunity to conducted RF disturbances
–
Power frequency field immunity
EN 50082-2
IEC / EN 61000-4-2
IEC / EN 61000-4-3
IEC / EN 61000-4-4
IEC / EN 61000-4-5
IEC / EN 61000-4-6
IEC / EN 61000-4-8
4 kV / 8 kV
10 V / m
2 kV
2 kV / 4 kV
10 V
30 A / m
Safety class
Degree of Protection 1
(IEC 536)
Case protection
IP 20
(IEC 529)
Enclosure material
Steel / Aluminium
Mounting
(snap-on with selflocking spring)
35 mm DIN-rails as per EN 50022
Connection
Screw terminals
(60
–
480 W models with
double terminals for output)
Industrial Power Supplies