TPS5140
FOUR-CHANNEL DC/DC CONTROLLER FOR NOTEBOOK PC POWER
SLVS305A – DECEMBER 2000 – REVISED JANUARY 2001
13
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage, VCC (see Note 1)
–0.3 V to 30 V
Input voltage; INV1/2/3, CT, PWM_SEL, REG5V_IN, SOFTSTART1/2/3, SOFTSTART_12V
–0.3 V to 7 V
.
SCP, PG_DELAY, PHASE_12V, OUT1/2/3_d, VREF3.3/5, FB1/2/3
–0.3 V to 7 V
. . . . . . . . . . .
PGOUT, EXT_PG
–0.3 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STBY1/2/3/12V, STBY_VREF3.3/5, TRIP1/2/3
–0.3 V to 30 V
. . . . . . . . . . . . . . . . . . . . . . . . . . .
VCC_SENSE12/3, LL1/2/3
–0.3 V to 30 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LL_UP, OUT_12V, IN_12V
–0.3 V to 16 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LH1/2/3, OUT1/2/3_u
–0.3 V to 35 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REF
–0.3 V to 3 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, TA (see Note 3)
– 20
°C to 85°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, Tstg
– 55
°C to 155°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values are with respect to the network ground terminal.
2. This rating is specified at duty = 10% on output rise and fall each pulse. Each pulse width (rise and fall) for the peak current should
not exceed 2
s.
3. See Dissipation Rating Table for free-air temperature range above 25
°C.
DISSIPATION RATING TABLE
PACKAGE
TA ≤ 25°C
POWER DISSIPATION
DERATING FACTOR
ABOVE TA = 25°C
TA = 85°C
POWER DISSIPATION
PAG
1811 mW
14.49 mW/
°C
941.6 mW
recommended operating conditions
MIN
NOM
MAX
UNIT
Supply voltage, VCC
4.5
28
V
INV1/2/3, CT, PG_DELAY, PWM_SEL SOFTSTART1/2/3 SOFT-
START_12V, SCP PHASE_12V, PGOUT, EXT_PG,
6
I
t
lt
V
REG5V_IN
–0.1
5.5
V
Input voltage, VI
STBY1/2/3/12V STBY_VREF3.3/5, TRIP1/2/3, VCC_SENSE12/3
–0.1
28
V
OUT1/2/3_u, LH1/2/3
–0.1
33
LL_UP, OUT_12V, IN_12V
–0.1
15
Oscillator frequency, fosc
CT capacitance
44
pF
Operation temperature range, TA
–20
85
°C
The recommended maximum operating frequency is typically 300 kHz.
electrical characteristics over recommended operating free-air temperature range, VCC = 7 V
(unless otherwise noted)
reference voltage
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
Vref
Reference voltage
1.185
V
V f(t l) Reference voltage tolerance
TA = 25°C,
I(vref) = 50 A
–1%
1%
Vref(tol) Reference voltage tolerance
I(vref) = 50 A
–1.5%
1.5%
Line regulation
VCC = 4.5 V to 28 V,
I(vref) = 50 A
0.05
3
mV
Load regulation
I(vref) = 0.1 A to 1 mA
0.15
5
mV