absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD
(see Note 1)
RESET, RESET, MR, WDI (see Note 1)
Maximum low output current, I
OL
Maximum high output current, I
OH
Input clamp current range, I
IK
(V
I
< 0 or V
I
> V
DD
)
Output clamp current range, I
OK
(V
O
< 0 or V
O
> V
DD
)
Continuous total power dissipation
Operating free-air temperature range, T
A
Storage temperature range, T
stg
Soldering temperature
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–
0.3 V to (V
DD
+ 0.3 V)
5 mA
–
5 mA
±
10 mA
±
10 mA
See Dissipation Rating Table
–
40
°
C to 85
°
C
–
65
°
C to 150
°
C
260
°
C
Stresses beyond those listed under
“
absolute maximum ratings
”
may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under
“
recommended operating conditions
”
is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to GND.
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
OPERATING FACTOR
ABOVE TA = 25
°
C
3.5 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
DBV
437 mW
280 mW
227 mW
recommended operating conditions
MIN
MAX
UNIT
Supply voltage, VDD
Input voltage, VI
High-level input voltage at MR and WDI, VIH
Low-level input voltage, VIL
Input transition rise and fall rate at MR or WDI,
t/
V
Operating free-air temperature range, TA
1.1
5.5
V
0
VDD + 0.3
V
0.7
×
VDD
V
0.3
×
VDD
100
V
ns/V
°
C
–
40
85