TMP01
REV. C
–3–
TMP01FJ–SPECIFICATIONS
TO99 Metal Can Package (V+ = +5 V, GND = OV, –40
8
C
≤
T
A
≤
+85
8
C
unless otherwse noted)
Parameter
Symbol
Conditions
Min
T yp
Max
Units
INPUT S SET HIGH, SET LOW
Offset Voltage
Offset Voltage Drift
Input Bias Current, “F”
OUT PUT VPT AT
1
Output Voltage
Scale Factor
T emperature Accuracy, “F”
T emperature Accuracy, “F”
T emperature Accuracy, “F”
T emperature Accuracy, “F”
Repeatability Error
Long T erm Drift Error
Power Supply Rejection Ratio
OUT PUT VREF
Output Voltage, “F”
Output Voltage, “F”
Output Voltage, “F”
Drift
Line Regulation
Load Regulation
Output Current, Zero Hysteresis
Hysteresis Current Scale Factor
T urn-On Settling T ime
OPEN-COLLECT OR OUT PUT S OVER, UNDER
Output Low Voltage
Output Low Voltage
Output Leakage Current
Fall T ime
POWER SUPPLY
Supply Range
Supply Current
Supply Current
Power Dissipation
V
OS
T CV
OS
I
B
0.25
3
25
mV
μ
V/
°
C
nA
100
VPT AT
T C
VPT AT
T
A
= +25
°
C, No Load
1.49
5
±
1.0
±
1.5
±
2
±
2.5
0.25
0.25
±
0.02
V
mV/K
°
C
°
C
°
C
°
C
Degree
Degree
%/V
T
A
= +25
°
C, No Load
10
°
C < T
A
< 40
°
C, No Load
–40
°
C < T
A
< 85
°
C, No Load
–55
°
C < T
A
< 125
°
C, No Load
Note 4
Notes 2 and 6
T
A
= +25
°
C, 4.5 V
≤
V+
≤
13.2 V
–3
3
–5.0
5.0
VPT AT
0.5
±
0.1
PSRR
VREF
VREF
VREF
T C
VREF
T
A
= +25
°
C, No Load
–40
°
C < T
A
< 85
°
C, No Load
–55
°
C < T
A
< 125
°
C, No Load
2.490
2.480
2.500
2.500
2.5
±
0.015
–10
±
0.01
±
0.1
7
5.0
25
2.510
2.520
V
V
V
ppm/
°
C
%/V
%/mA
μ
A
μ
A/
°
C
μ
s
4.5 V
≤
V+
≤
13.2 V
10
μ
A
≤
I
VREF
≤
500
μ
A
±
0.05
±
0.25
I
VREF
SF
HYS
(Note 1)
T o Rated Accuracy
V
OL
V
OL
I
OH
t
HL
I
SINK
= 1.6 mA
I
SINK
= 20 mA
V+ = 12 V
See T est Load, Note 2
0.25
0.6
1
40
0.4
V
V
μ
A
ns
100
V+
I
SY
I
SY
P
DISS
4.5
13.2
500
800
2.5
V
μ
A
μ
A
mW
Unloaded, +V = 5 V
Unloaded, +V = 13.2 V
+V = 5 V
400
450
2.0
NOT ES
1
K =
°
C + 273.15.
2
Guaranteed but not tested.
3
Does not consider errors caused by heating due to dissipation of output load currents.
4
Maximum deviation between +25
°
C readings after temperature cycling between –55
°
C and +125
°
C.
5
T ypical values indicate performance measured at T
= +25
°
C.
6
Observed in a group sample over an accelerated life test of 500 hours at 150
°
C.
Specifications subject to change without notice.