PROGRAMMABLE OVERVOLTAGE PROTECTORS
section 4.5.12 - first-level power fault testing
The most significant tests are a long duration (900 s) medium current test and a higher current tests of 60 one
second power applications. As shown in table 4, the peak currents for these tests are 2x0.37 A and 2x1.3 A
respectively. The TISP61089S will survive both these conditions as its ratings are 2x0.93 A and 2x4.5 A for
these time periods
Using a 25
series resistor will result in table 4. I
TM
column values of 2x0.45, 2x0.9, 2x1.4, 2x1.4, 2x0.4 and
2x0.23. The TISP61089S will survive these peak current values as they are lower than the TISP61089S
ratings.
section 4.5.13 - second-level power fault testing
The two most significant tests are a long duration (900 s) medium current test and a higher current 5 s test.
As shown in table 5, the peak currents for these tests are 2x17 A and 2x7.7 A respectively. For the
TISP61089S to survive this test, the series current limiting element must operate within 0.1 s and 0.5 s
respectively.
table 4. first-level power fault currents
A.C.
DURATION
s
OPEN-CIRCUIT
RMS VOLTAGE
V
SHORT-CIRCUIT
RMS CURRENT
A
SOURCE
RESISTANCE
TOTAL CIRCUIT
RESISTANCE
I
TRMS
A
I
TM
A
1
200
0.33
600
640
2x0.31
2x0.44
1
400
0.67
600
640
2x0.63
2x0.88
1
600
1
600
640
2x0.94
2x1.3
1
1000
1
1000
1040
2x0.96
2x1.3
900
50
0.33
150
190
2x0.26
2x0.37
100
0.17
590
630
2x0.16
2x0.22
table 5. second-level power fault currents
A.C.
DURATION
s
OPEN-CIRCUIT
RMS VOLTAGE
V
SHORT-CIRCUIT
CURRENT
A
SOURCE
RESISTANCE
TOTAL
CIRCUIT
RESISTANCE
I
TRMS
A
I
TM
A
5
600
60
10
50
2x12
2x17
5
600
7
86
126
2x4.8
2x6.8
900
120
25
5
45
2x2.7
2x3.8
900
277
25
11
51
2x5.4
2x7.7
900
100
0.37
273
313
2x0.32
2x0.45
900
300
1.1
273
313
2x0.96
2x1.4
900
600
2.2
273
313
2x1.9
2x2.7