DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage, V
CC
Input voltage, V
I
Output current, I
O
Differential input voltage, V
IO
Continuous total power dissipation
Maximum junction temperature, T
J
Operating free-air temperature, T
A
:
±
16.5 V
±
V
CC
150 mA
±
4 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-suffix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I-suffix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
See Dissipation Rating Table
150
°
C
0
°
C to 70
°
C
–40
°
C to 85
°
C
–65
°
C to 150
°
C
300
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
DISSIPATION RATING TABLE
PACKAGE
θ
JA
(
°
C/W)
167
θ
JC
(
°
C/W)
TA = 25
°
C
POWER RATING
D
38.3
740 mW
DGN§
58.4
4.7
2.14 W
This data was taken using the JEDEC standard Low-K test PCB. For the JEDEC Proposed
High-K test PCB, the
θ
JA is 95
°
C/W with a power rating at TA = 25
°
C of 1.32 W.
§This data was taken using 2 oz. trace and copper pad that is soldered directly to a 3 in.
×
3 in.
PC. For further information, refer to Application Informationsection of this data sheet.
recommended operating conditions
MIN
±
5
10
NOM
MAX
±
15
UNIT
Supply voltage VCC and VCC
Supply voltage, VCC+ and VCC–
Dual supply
V
Single supply
30
Operating free air temperature TA
Operating free-air temperature, TA
C-suffix
0
70
°
C
I-suffix
–40
85