http://www.tracopower.com
Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TEN 6 Series
6 Watt
Input Specifications
Input current no load /full load
Start-up voltage /
under voltage shut down
Surge voltage
(1 sec. max.)
Reverse voltage protection
Conducted noise
(input)
Output Specifications
Voltage set accuracy
Regulation
Ripple and noise
(20 MHz Bandwidth)
Temperature coefficient
Current limitation
Short circuit protection
Capacitive load
General Specifications
Temperature ranges
Derating
Humidity
(non condensing)
Reliability, calculated MTBF
(MIL-HDBK-217 E)
Isolation voltage
Isolation capacity
Isolation resistance
Switching frequency
Safety standards
Safety approval
24 Vin models
22 mA / 600 mA typ.
(at 12 VDC Vin)
20 mA / 300 mA typ.
(at 24 VDC Vin)
48 Vin models
11 mA / 300 mA typ.
(at 24 VDC Vin)
10 mA / 150 mA typ.
(at 48 VDC Vin)
24 Vin models
8.5 VDC / 8.0 VDC typ.
48 Vin models
17 VDC / 16 VDC typ.
24 Vin models
50 V max.
48 Vin models
100 V max.
1.0 A max.
EN 55022 level A, FCC part 15, level A
– Input variation Vin min. to Vin max.
– Load variation 10 – 100 %
– single output models
– dual output models balanced load
– dual output models unbalanced load
± 1 %
± 0.3 % max.
± 1.0 % max.
± 1.0 % max.
± 3.0 % max.
75 mVpk-pk max
± 0.02 % / K
> 110% of Iout max., constant current
indefinite (automatic recovery)
3’000 μF max.
680 μF max.
– single output models
– dual output models
– Operating
– Case temperature
– Storage
– 40 °C ... + 85 °C
+ 100 °C max.
– 55 °C ... + 125 °C
3.5% /K above 70°C
95 % rel H max.
>1 Mio. h @ + 25 °C
1’500 VDC
380 pF typ
> 1‘000 M Ohm
300 kHz typ. (Pulse frequency modulation PFM)
UL/cUL 60950 , IEC 60950, EN 60950
Compliance up to 60 VDC input voltage
(SELV limit)
CSA (File no. 226037)
Input/Output
Input/Output
Input/Output (500 VDC)