ELECTRICAL CHARACTERISTICS
(V
CC
= 12V, T
amb
= 25
o
C unless otherwise specified)
Symbol
V
CC
I
Q
I
p0
I
n0
I
o0
Parameter
Test Conditions
Min.
7
10
1.5
2
120
50
Typ.
Max.
18
25
Unit
V
mA
A
A
mA
mA
Supply Voltage
Quiescent Current
Positive Output Current (source)
Negative Output Current (sink)
Positive quiescent output current forcing
the output to 6 V and the sense input to
ground, output externally forced to 6V
Transconductance ON Phase (1)
Transconductance OFF Phase (2)
Transconductance Standby Mode
Current Source Pin 5
Sense Input Resistance
All Inputs Open
15
Remote Input 1
Remote Input 0
150
80
200
100
G
ON
G
OFF
G
REMOTE
I
5
R
INS
See Figure 1
See Figure 1
Remote Input 0
V
6
= 500mV
V
S
> 0
V
S
< 0
V
S
= 0, Remote Input 1
V
SYN
< 7V
V
SYN
> 7V
1.8
1.8
0.675
135
0.7
0.35
– 200
30
7
1
2.0
2.0
0.75
165
1
0.5
– 300
60
10
1.8
2.2
2.2
0.825
200
1.3
0.7
– 400
150
15
2.8
A/V
A/V
A/V
μ
A
k
k
μ
A
k
k
V
I
INS
R
SYN
Sense Input Bias Current
Synchronous Detection Input Resistance
V
THS
Threshold Voltage of the Synchronous
Detection Input
Sync Detect Input Voltage
Threshold Voltage of Control Input
Pull up Current of Control Input
V
SYN
V
THA
I
INA
30
2.5
– 160
+ 1
2.5
– 160
+ 1
300
4.5
3
7.0
6.8
V
V
μ
A
μ
A
V
μ
A
μ
A
μ
s
μ
s
V
V
V
1.5
– 50
- 1
1.5
– 50
– 1
190
2
0 < V
IN
< V
THA
V
IN
> V
THA
+ 0.5V
– 100
0
2
– 100
0
250
3
2.8
6.4
V
– 0.2 V
0.9
V
THB
I
INB
Threshold Voltage Remote Input
Pull up Current of the Remote Input
0 < V
< V
V
IN
> V
THB
+ 0.5V
t
dr
t
don
Remote Delay Time (3)
On Delay Time
Output Voltage Drop for I
p0
= 1 A
Supply Voltage for Device "ON"
Supply Voltage for Device "OFF"
(output internally switched to ground)
Sense Limit Voltage (4)
1. G
ON
is measured with V
3
varying from 150mV to 350mV (Pin 5 is grounded)
2. G
is measured with V
varying from 150mV to 350mV (Pin 3 is grounded)
3. When the remote input goes from HIGH to LOW the BU508 is switched off and it remains in this condition for the time t
.
4. The sense input voltage V
is internally limited and results in a limited positive output current I
= g V
limit. Note that due to
the storage time t
of the BU508 limiting of V
S
leads to a reduced base current of the BU508 and the output current I
0
is going to
the positive quiescent current I
O0
.
V
CC
–V
OUT
V
CC ON
V
CC OFF
2
I
0
≥
0
5.8
5.6
V
S limit
0.8
1
V
8
Notes :
TRUTH TABLE
Logic Inputs
Output I
o
Mode
Control Input
Remote/Standby
Floating or 1
Floating or 1
0
Floating or 1
I
o
> 0
I
o
< 0 (5)
I
o
< 0 (5)
0 < t < t
dr
I
> 0
t > td
r
BU508 ON
BU508 OFF
BU508 OFF
Normal Function
X
0
Remote/Standby
Function
X
0
BU508 ON
8
Note :
5. I
O
< 0 means that the sink current flows into the output to ground.
TDA8140