2-15
TELCOM SEMICONDUCTOR, INC.
7
6
5
4
3
1
2
8
TC620
TC621
TC620/1-9 11/4/96
FUNCTIONAL BLOCK DIAGRAM
3
HIGH SET
2
LOW SET
5
CONTROL*
6
HIGH LIMIT
V
DD
7
LOW LIMIT
8
4
*Suffix code "C" denotes cooling option (high true CONTROL output);
Q
S
R
Q
+
+
–
–
TC620
HIGH SET
LOW SET
1
THERMISTOR
CONTROL*
HIGH LIMIT
LOW LIMIT
Temp
to
Voltage
Converter
V
GEN
V
GEN
V
REF
3
2
5
6
V
DD
7
8
4
Q
S
R
Q
+
+
–
–
TC621
Thermistor
Interface
Circuit
V
GEN
V
GEN
V
REF
Ambient
Temperature
– 40
°
C to +85
°
C
– 40
°
C to +85
°
C
Part No.
Package
TC621x*EOA
TC621x*EPA
8-Pin SOIC
8-Pin Plastic DIP
5V, DUAL TRIP POINT TEMPERATURE SENSORS
FEATURES
I
User-Programmable Hysteresis and Temperature
Set Point
Easily Programs with 2 External Resistors
Wide Temperature Detection
Range................ – 40
°
C to +125
°
C (TC620/621CVx)
External Thermistor for Remote Sensing
Applications (TC621x)
I
I
I
APPLICATIONS
I
I
I
I
Power Supply Overtemperature Detection
Consumer Equipment
Temperature Regulators
CPU Thermal Protection
ORDERING INFORMATION
Ambient
Temperature
0
°
C to +70
°
C
0
°
C to +70
°
C
– 40
°
C to +85
°
C
– 40
°
C to +85
°
C
– 40
°
C to +125
°
C
0
°
C to +70
°
C
0
°
C to +70
°
C
Part No.
Package
TC620x*COA
TC620x*CPA
TC620x*EOA
TC620x*EPA
TC620CVOA
TC621x*COA
TC621x*CPA
8-Pin SOIC
8-Pin Plastic DIP
8-Pin SOIC
8-Pin Plastic DIP
8-Pin SOIC
8-Pin SOIC
8-Pin Plastic DIP
*The part code will be C or H (see Functional Block Diagram, below,
and page 2).
GENERAL DESCRIPTION
The TC620 and TC621 are programmable logic output
temperature detectors designed for use in thermal manage-
ment applications. The TC620 features an on-board tem-
perature sensor, while the TC621 connects to an external
NTC thermistor for remote sensing applications.
Both devices feature dual thermal interrupt outputs
(HIGH LIMIT and LOW LIMIT), each of which program with
a single external resistor. On the TC620, these outputs are
driven active (high) when measured temperature equals the
user-programmed limits. The CONTROL (hysteresis) out-
put is driven high when temperature equals the high limit
setting, and returns low when temperature falls below the
low limit setting. This output can be used to provide simple
ON/OFF control to a cooling fan or heater. The TC621
provides the same output functions except that the logical
states are inverted.
The TC620/621 are usable over a maximum tempera-
ture range of – 40
°
C to +125
°
C.