Test Conditions
(
Unless otherwise specified, V
CC
= 5 V (Pins 2 & 15), Ta = 25°C)
Note
Item
Test Condition
1
Bell / Filter f
0
(1) : Input a 20 mV
p-p
sine wave whose frequency is sweep
into Pin 20.
(2) : Connect Pin 20 to GND through 27 k
.
(3) : Keep Pin 24 GND.
(4) : Measure the frequency at which the Pin 7 output is the
greatest, that is, "f
0BEL
".
(5) : Calculate
:
"f
0B-C
" = f
0BEL
4,286 kHz.
2
Bell / Filter f
0
Variable Range
(1) : Input a 20 mV
p-p
sine wave whose frequency is sweep into Pin
20.
(2) : Connect pin 20 to GND through 27 k
.
(3) : Measure the frequency at which the Pin 7 output is the greatest
when V
CC
is 5.5 V / 4.5 V, that is, f
0BEL5.5
/ f
0BEL4.5
.
(4) : Calculate
:
"f
0B-H
" = f
0BELH
4,286 kHz.
f
0B-L
" = f
0BELL
4,286 kHz.
3
Bell / Filter Q
(1) : Input a 20 mV
p-p
sine wave whose frequency is sweep into Pin
20.
(2) : Connect Pin 20 to GND through 27 k
.
(3) : Pin 24 is GND.
(4) : Observe the frequency response of the Pin 7 output.
(5) : Calculate
:
"Q
BEL
" = (MAX
3dB Band Width) / f
0BEL
.
4
Color Difference Output
Amplitude
(1) : Input a 75% color bar (200 mV
p-p
at R ID) into Pin 20.
(2) : Measure the R-Y output amplitude at Pin 9, that is, "V
RS
".
(3) : Measure the B-Y output amplitude at Pin 11, that is, "V
BS
".
5
Color Difference Relative
Amplitude
Calculate : "R / B-S" = V
RS
/ V
BS
.
6
Linearity
(1) : Input a 75% color bar (200 mV
p-p
at R ID) into Pin 20.
(2) : Measure the amplitude between Black and Cyan / Red,
that is, V
Cyan
/ V
Red
.
(3) : Measure the amplitude between Black and Yellow /
Blue, that is, V
Yellow
/ V
Blue
.
(4) : Calculate : "LinR" = V
Cyan
/ V
Red
"LinB" = V
Yellow
/ V
Blue
7
Rising Time
(1) : Input a 75% color bar (200 mV
p-p
at R ID)
into Pin 20.
(2) : Measure the rising time (from 10% to 90%)
between Green and Magenta at Pin 9 / Pin 11, that is,
"t
rR
" / "t
rB
".
8
Demodulation Hold Range
9
Demodulation Capture Range
(1) : Input a 200 mV
p-p
, 2 MHz sine wave into Pin 20.
(2) : Increasing the input frequency, measure the
frequencies at which demodulated output
appears at Pin 9, that is, "C
RL
", and at which
demodulated output disappears at Pin 11, that is,
"H
BH
".
(3) : Input a 200 mV
p-p
, 7 MHz sine wave into Pin 20.
(4) : Decreasing the input frequency, measure the frequencies at which demodulated
output appears at Pin 11, that is, "C
BH
", and at which demodulated output
disappears at Pin 9, that is, "H
RL
".