Advance Data Sheet
March 2001
T92-Type 10 Gbits/s 1300 nm
Uncooled DFB Laser Transmitter
3
Agere Systems Inc.
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Characteristics
(Minimum and maximum values specified over operating case temperature range at 50% duty cycle data signal.
Typical values are measured at room temperature unless otherwise noted.)
1. With V
EE
connected to –5.2 V, V
CC
must be at 0 V; With V
CC
connected to +5.0V, V
EE
must be at 0 V.
2. Inputs are ac-coupled into an equivalent input impedance of 50
.
3. Single-ended or differential operation may be used. If the inputs are driven single-ended, the unused inputs (
Clock
and
Data
) must be 50
ter-
minated to ground.
4. Clocked operation is normally enabled and only requires an external voltage to disable. For nonclocked operation, pin 5 must be tied to V
CC
.
5. With clocked operation, the optical output changes state with the rising edge of the input clock signal. The skew is measured with the rising
edge of the clock centered in the middle of the data eye.
6. The transmitter is normally enabled and only requires an external voltage to disable.
7. This alarm will go active when the bias current to the laser has increased 50% or more from its beginning-of-life (BOL) value.
8. This voltage is measured from Pin 3 to V
EE
and is converted to laser bias current with the ratio of 20 mV/mA.
9. This voltage is measured from Pin 2 to V
EE
.
Parameter
Symbol
V
CC
T
C
T
stg
—
RH
—
Min
—
0
–40
—
—
Max
5.5
70
85
250/10
85
—
Unit
V
°C
°C
°C/s
%
in. (mm)
Supply Voltage
Operating Case Temperature Range
Storage Case Temperature Range
Lead Soldering Temperature/Time
Relative Humidity (noncondensing)
Minimum Fiber-Bend Radius
1.00 (25.4)
Table 2. Electrical Characteristics
Parameter
Symbol
V
EE
I
V
IN
Min
Typ
Max
Unit
V
mA
mVp-p
dc Power Supply Voltage
1
dc Power Supply Current Drain
Input Data/Clock Voltage:
2, 3
Single-ended Input
Clocked/Nonclocked Select Voltage:
4
Clocked Operation
Nonclocked Operation
Clock/Data Input Impedance
Clock/Data RF Return Loss (50 kHz to 10 Ghz)
Clock/Data Input Skew
5
Transmitter Disable Voltage
6
Transmitter Enable Voltage
Degrade Mode Alarm Voltage–Normal
Degrade Mode Alarm Voltage–Alarmed
7
Laser Bias Voltage
8
Back-facet Monitor Voltage (50% duty cycle)
9
–5.5/+4.75
—
500
–5.2/+5.0
250
700
–4.9/+5.25
400
1000
V
SEL_CLK
V
SEL CLK
R
IN
S11
dc
SKEW
V
DIS
V
EN
V
NORMAL
V
ALARMED
V
B
V
BF
V
EE
V
CC
– 2.0
—
—
–25
V
CC
– 2.0
V
EE
V
CC
– 2.0
V
EE
0
460
—
—
50
—
0
—
—
—
—
500
500
V
EE
+ 0.8
V
CC
—
–10
25
V
CC
V
EE
+ 0.8
V
CC
V
EE
+ 0.8
2400
540
V
V
dB
ps
V
V
V
V
mV
mV