2-15
FOR FURTHER TECHNICAL
DETAILS ON THIS PRODUCT
REQUEST CATALOGUE
REFERENCE
E142-A
S
OLENOID
V
A LV ES
S
ERIES
SY 100
V
Castle Hill NSW.............Tel: (02) 680 3222.....Fax: (02) 894 5719
V
O R D E R L IN E S
DETA ILS OF Y OUR LOCA L SA LES OFFICE
3/2 D
IRECT
A
CTING
S
OLENOID
V
A LV E
0.5 w Power Consumption (standard type
Life in excess of 10M cycles
Compact (10mm body width)
Light weight
Suitable for low vacuum
Modern light colour
Copper free as standard
APPLICATIONS
Small single acting cylinder
Pilot valves
Vacuum suitability
Air blast eject valves
Note: Body ported version (SY 1*3*) is available either as a
“ stand alone” valve (order with PM3 piping option) or
with a common supply manifold (order as M3 piping)
SY1**
SY1**A
Fluid
Ambient & Fluid temp
Response time
Max operating frequency
Lubrication
Mounting Direction
Available Voltage Dc
Ac
Allowable Voltage Variation
Cv (effective orifice mm
2
)
Power Consumption
Air
50°C max.
10ms (without surge voltage & suppression)
20Hz
Not required
Free
24, 12, 6, 5, 3 VDC
24, 110, 220 Ac
-10% ~+10%
0.008 (0.14)
0.5w (0.55w with LED)
110v 1.0VA (1.1VA wth LED)
230v 2.2VA (2.3VA with LED)
0~0.7MPa (0–7.1kgf/cm
2
N/a
0.012 (0.22)
0.75w (0.8w with LED)
N/A
N/A
Dc
Ac
Operating Pressure Range
T
E C H N IC A L
S
PECIFICATIONS
S
Y M B O L S
Single Subbase
Connector Assemblies
SY100-74-1
See Series SY3000
A
CCESSORIES
H
O W
O
SY 100 V
A LV E
– M
A NIF O L D S
F
O R
B
O D Y
P
O R T E D
V
A LV E S
SY 113(A )
U
LT R A C O M PA C T T Y PE W IT H C O M M O N E X H A U ST
SS3Y1
30
N
O O F
S
TA T IO NS
02 .....2 Stations
:
10 .....10 Stations
T
O
R D E R
F
P
IPE D E X H A U ST T Y PE F O R
SY 1113(A )
A ND
SY 123(A )
SS3Y1
31
N
O O F
S
TA T IO NS
02 .....2 Stations
:
.20 ....20 Stations
Note: SY123 and SY113 cannot
be mixed on the same
manifold
F
O R
B
A SE
M
O U NT
V
A LV E S
SY 1*4(A )
SS3Y1
S41
N
O O F
S
TA T IO NS
02 .....2 Stations
:
20 .....20 Stations
A P
O R T
S
IZ E
M3.....M3 port
M5.....M5 port
Blanking Plate (All types)
Spare Gasket (Body Ported Valves)
Spare Gasket (Base Mounted Valves) VJ100-6-1
SY100-77-1A
VJ100-6-2
M
A NIFOLD
A
CCESSORIES
Note: SY124 and SY114
cannot be mixed on
the same manifold
O
PE R A T IO N
1 .......Normally closed
2 .......Normally open
P
O R T ING
3 .......Body Ported
4 .......Base Mount
F
L O W
Nil .....Standard (Cv = 0.008)
A .......Large Flow (Cv = 0.012)
V
O LTA G E
5 .......24VDC
6 .......12VDC
V .......6VDC
S .......5VDC
R .......3VDC
B .......24vAc
3 .......110vAC
4 .......230vAC
Note: Ac types for
standard flow
version only
E
L E C T R IC A L
E
NT R Y
L
A M P
& S
U R G E
P
R O T E C T IO N
Nil .....W ithout
S .......Surge voltage & suppressor
Z .......Lamp & Surge Suppressor
P
IPING
O
PT IO N
Nil .....For manifold (SY1*4 only)
M3.....For manifold (SY1*3 only)
PM3 ...Body port (SY1*3 only)
PM3-F Body Port with bracket (SY1*3 only)
H
O W
O
T
O
R D E R
SY1
Q