5
ECL Pro
SY100EP57V
Micrel, Inc.
M9999-120505
hbwhelp@micrel.com or (408) 955-1690
TA = –40°CTA = +25°CTA = +85°C
Symbol
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
Condition
VIL
Input LOW Voltage
–1945
—
–1625 –1945
—
–1625 –1945
—
–1625
mV
VIH
Input HIGH Voltage
–1225
—
–880
–1225
—
–880
–1225
—
–880
mV
VOL
Outuput LOW Voltage
–1945 –1820 –1695 –1945 –1820 –1695 –1945 –1820 –1695
mV
50 to VCC–2V
VOH
Output HIGH Voltage
–1145 –1020
–895
–1145 –1020
–895
–1145 –1020
–895
mV
50 to VCC–2V
VBB
Output Reference Voltage
–1525 –1425 –1325 –1525 –1425 –1325 –1525 –1425 –1325
mV
VIHCMR
Input HIGH Voltage(2)
V
EE +2.0
0.0
V
EE +2.0
0.0
V
EE +2.0
0.0
V
Common Mode Range
(100KEP) ECL/LVECL DC ELECTRICAL CHARACTERISTICS(1)
VCC = 0V, VEE = –5.5V to –3.0V
Notes:
1. 100KEP circuits are designed to meet the DC specifications shown in the above table after thermal equilibrium has been established. The circuit is in
a test socket or mounted on a printed circuit board and traverse airflow greater than 500lfpm is maintained. Input and output parameters are at V
CC =
3.3V. They vary 1:1 with V
CC.
2. The V
IHCMR range is referenced to the most positive side of the differential input signal.
TA = –40°CTA = +25°CTA = +85°C
Symbol
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
Condition
fMAX
Max. Toggle Frequency(1)
3—
—3—
—
3—
—
GHz
tPLH
Propagation Delay (Differential)
tPHL
D to Q, /Q
250
310
450
250
315
475
250
320
520
ps
SEL to Q, /Q
300
370
500
300
380
520
300
390
575
ps
tSKEW
Part-to-Part Skew(2)
—
200
—
200
—
200
ps
tJITTER
Cycle-to-Cycle Jitter (rms)
—
0.2
< 1
—
0.2
< 1
—
0.2
< 1
psRMS
Random Jitter
————
<1
————
psRMS
Note 3
Deterministic Jitter
@1.25Gbps
————
<25
————
psPP
Note 4
@2.5Gbps
————
<50
————
VDIFF
Input Voltage (Differential)
150
800
1200
150
800
1200
150
800
1200
mV
tr, tf
Output Rise/Fall Time Q, /Q
—
120
170
—
140
200
—
150
220
ps
(20% to 80%)
Notes:
1. Measured with 750mV input signal, 50% duty cycle. Output swing ≥ 400mV. All loading with a 50 to VCC –2.0V.
2. Skew is measured between outputs under identical transitions. Duty cycle skew is defined only for differential operation when the delays are
measured from the cross point of the inputs to the cross point of the outputs.
3. RJ is measured with a K28.7 comma detect character pattern, measured at 1.25Gbps and 2.5Gbps.
4. DJ is measured at 1.25Gbps and 2.5Gbps, with both K28.5 and 223–1 PRBS pattern.
AC ELECTRICAL CHARACTERISTICS
VCC = 0V; VEE = –3.0V to –5.5V or VCC = 3.0V to 5.5V, VEE = 0V